AT-FS709FC10/100 Fast Ethernet Unmanaged SwitchInstallation GuidePN 613-10817-00 Rev. A
Product Description4MDI/MDI-X Port 8Port 8 is associated with the MDI function.Port 8 gives you the flexibility of using a straight-through cable to c
5Chapter 2InstallationBefore you ProceedBefore installing the switch, make sure you read “Electrical Safety and Installation Requirements” on page 15.
Installation6Site RequirementsMake sure you observe the following site requirements:!Make sure you are placing the switch in a dust-free and moisture-
AT-FS709FC Installation Guide7NoteDo not plug a phone jack connector into any RJ45 port. This may damage the switch. Use only twisted-pair cables with
Installation86. Attach the data cables and observe normal operation as indicated by the port LEDs. Use only one Port 8, either Port 8 MDI or Port 8 MD
AT-FS709FC Installation Guide9Cascade ConfigurationCascading means that two switches can be connected together using any of the switch ports, provided
Installation10Uplink ConfigurationFor 100 Mbps connection to the backbone, use Port 9. Figure5 illustrates how this switch can be used as a full-duple
11Chapter 3TroubleshootingThis chapter describes the procedures to test and troubleshoot the switches.Connectivity TestingIn the following procedure,
Troubleshooting12Problem SolvingIs the unit receiving power?Check the Power LED on the front of the switch. This green LED should be lit. NoteThe swit
AT-FS709FC Installation Guide134. Problem 4:There is data loss between the switch and one of the connected network nodes.!Solution 4:— Make sure that
Copyright 1999 Allied Telesyn International, Corp.960 Stewart Drive Suite B, Sunnyvale CA 94086, USAAll rights reserved. No part of this publication
15Appendix AElectrical Safety and Installation RequirementsSTANDARDS: This product meets the following standards.U.S. Federal Communications Commissio
Electrical Safety and Installation Requirements16RADIATED ENERGYRFI Emission EN55022 Class BWARNING: This product requires shielded cables to comply w
AT-FS709FC Installation Guide17CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling.OPERATING TEMPERAT
Electrical Safety and Installation Requirements18BETRIEBSTEMPERATURDieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr al
AT-FS709FC Installation Guide19BETJENINGSTEMPERATURDette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C.ALLE LANDE: Instal
Electrical Safety and Installation Requirements20OPGELET: De ventilatiegaten mogen niet worden gesperd en moeten de omgevingslucht ongehinderd toelate
AT-FS709FC Installation Guide21ATTENTION: Ne pas bloquer les fentes d’aération, ceci empêcherait l’air ambiant de circuler librement pour le refroidis
Electrical Safety and Installation Requirements22HUOMAUTUS: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys ympäröivään huoneilmaan
AT-FS709FC Installation Guide23ATTENZIONE: le prese d’aria non vanno ostruite e devono consentire il libero ricircolo dell’aria ambiente per il raffre
iiiSafety WarningsSTANDARDS: This product meets the following standards.U.S. Federal Communications CommissionDECLARATION OF CONFORMITYManufacture Nam
Electrical Safety and Installation Requirements24DRIFTSTEMPERATURDette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader celsius.
AT-FS709FC Installation Guide25CUIDADO: As aberturas de ventilação não devem ser bloqueadas e devem ter acesso livre ao ar ambiente para arrefecimento
Electrical Safety and Installation Requirements26ATENCION: Las aberturas para ventilación no deberán bloquearse y deberán tener acceso libre al aire
AT-FS709FC Installation Guide27DRIFTSTEMPERATURDenna produkt är konstruerad för rumstemperatur ej överstigande 40 grader Celsius.ALLA LÄNDER: Install
29Appendix BSwitch SpecificationsPhysical CharacteristicsChassis dimensions: L x W x H13 in x 8.0 in x 1.72 in330 mm x 203 mm x 44 mmWeight: 4 lbs (2.
Switch Specifications30Cable SpecificationsTable 4 IEEE 802.3 and 802.3u Network Specifications10Base-T 100Base-TXMedia Shielded Twisted PairCategory
31Appendix CTechnical Support Fax OrderName___________________________________________________________________Company ________________________________
33Appendix DAT-FS709FC Installation FeedbackPlease tell us what additional information you would like to see discussed in the guide. If there are topi
Safety WarningsivWARNING: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate
35Appendix EWhere To Find UsFor Technical Support or ServiceLocation Phone FaxAmericasUnited States, Canada, Mexico, Central America, South America1 (
vTable of ContentsSafety Warnings... i
viAppendix CTechnical Support Fax Order...31Incident Summary
1Chapter 1Product DescriptionOverviewThe AT-FS709FC is a nine port Fast Ethernet switch with eight auto-negotiating 10Base-T/100Base-TX shielded twist
Product Description2Figure 1 shows the switch front panel. Figure 1 AT-FS709FC Front PanelDescriptionThis section includes:!Connectors!LEDs!MDI/MDI-X
AT-FS709FC Installation Guide3LEDsFigure 2 illustrates the switch front panel LEDs. Table 2 lists and describes these LEDs.Figure 2 A Close Up of the