Allied-telesis AT-FS203 Manual do Utilizador Página 35

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 34
AT-FS200 Series Installation Guide
25
Table 10
Fiber Optic Receiver
Model
Fiber
Type
Fiber
Optic
Diameter
(microns)
Optical
Frequency
(nm)
Receive Power (dBm)
Min.
Sensi-
tivity
Typical
Sensi-
tivity
Satura-
tion
AT-FS201 &
AT-FS202
MMF 50/125 1310 nm -31.8 -34.5 -14.0
MMF 62.5/125 1310 nm -31.8 -34.5 -14.0
AT-FS201ST/FS1 &
AT-FS202SC/FS1
SMF 9/125 1310 nm -31.0 -31.0 -8.0
AT-FS201ST/FS2 &
AT-FS202SC/FS2
SMF 9/125 1310 nm -35.0 -38.0 0.0
AT-FS201ST/FS3 &
AT-FS202SC/FS3
SMF 9/125 1310 nm -37.0 -37.0 -3.0
Table 11
Fiber Optic Datalink
Model Fiber Type
Min.
Power /
Link
Budget
(dB)
Avg.
Signal
Loss
(dB)
Min.
Distance
Specs.
1
1. The recommended minimum range is stated in all cases where the maximum trans
mitter output power exceeds the receivers saturation level. This is to prevent blind-
ing or burning out of the optical receiver on the far-end node.
Max.
Distance
Specs.
AT-FS201 &
AT-FS202
50/125 MMF 13.00 18.70 0 2 km
(1.25 mi)
62.5/125
MMF
16.80 22.50 0 2 km
(1.25 mi)
AT-FS201ST/FS1 &
AT-FS202SC/FS1
9/125 SMF 16.00 19.50 0 15 km
(9.4 mi)
AT-FS201ST/FS2 &
AT-FS202SC/FS2
9/125 SMF 30.00 35.00 0 40 km
(25 mi)
AT-FS201ST/FS3 &
AT-FS202SC/FS3
9/125 SMF 33.00 35.00 15 km
(9.4 mi)
75 km
(46 mi)
Vista de página 34