Technical Specifications
20
Table 8 Fiber Optic Loss Specification (Benchmarks)
Pinout Assignments
Figure 7 shows the pin assignments of the RJ-45 connector.
Figure 7 RJ-45 Pin Assignments
Table 9 lists the 100Base-TX connector pins and their signals when the port is
operating in either MDI or MDI-X configuration.
Table 9 RJ-45 Pin Signals
Fiber Type
Fiber Optic
Diameter
Optical
Frequency
Typical
Loss Factor
Worst Case
Loss Factor
Bandwidth
Multimode
Fiber
50/125 1310 nm 1.00 db/km 1.50 db/km 400
62.5/125 1310 nm 1.00 db/km 1.5 db/km 500
Single-mode 9/125 nm 1310 nm 0.40 db/km 1.00 db/km N/A
9/125 nm 1550 nm 0.30 db/km 0.75 db/km N/A
MDI-X (Default) Signal MDI Signal
1RX+1 TX+
2RX-2 TX-
3 TX+ 3 RX+
4- 4 -
5- 5 -
6 TX- 6 RX-
7- 7 -
8- 8 -
Pin 1 Pin 8