Chapter 9: User Diagnostics
118
Performing Diagnostics
At the MS-DOS prompt, type uxdiag followed by the command options.
The uxdiag command options are shown in Table 7. For example, to run
all diagnostic tests except Group B tests on adapter #1, enter the following
command:
C:\>uxdiag -c 1 -t b
Note
You must include uxdiag at the beginning of the command string
each time you type a command.
Table 7. uxdiag Command Options
Command Options Description
uxdiag Performs all tests on all Broadcom
NetXtreme II adapters in your system.
uxdiag -c <devnum> Specifies the adapter (devnum) to test.
Use all in place of a specific device
number to test all adapters.
uxdiag -cof Allows tests to continue after detecting
a failure.
uxdiag -F Forces an upgrade of the image
without checking the version.
uxdiag -fbc <bc_image> Specifies the bin file to update the
bootcode.
uxdiag -fib <ib_image> Specifies the bin file for iSCSI boot.
uxdiag -fibc Programs the iSCSI configuration
block. Used only with -fib <ib_image>.
uxdiag -fibp Programs the iSCSI configuration
software. Used only with -fib
<ib_image>.
uxdiag -fipmi
<ipmi_image>
Specifies the bin file to update IPMI
firmware.
uxdiag -fmba
<mba_image>
Specifies the bin file to update the
MBA.
uxdiag -fncsi
<ncsi_image>
Specifies the bin file to update the
NCSI firmware.