Chapter 17: Event Log and Syslog Server Commands
270
ENABLE LOG OUTPUT
Syntax
enable log output[=id_number]
Parameters
output Specifies the ID number of the syslog server
definition you want to enable. The range is 2 to 20.
You can specify only one ID number at a time.
Omitting an ID number enables all syslog server
definitions.
Description
This command enables the specified syslog server definition that was
disabled using DISABLE LOG OUTPUT on page 268. When a syslog server
definition is enabled, the switch immediately begins to send events to
the server.
Examples
The following command enables syslog server definition 4:
enable log output=4
The following command activates all syslog server definitions:
enable log output