Allied Telesyn AT-VIEW PLUS
DEVICE MANAGER
6.4.8 Set MIB Value Button
: Changes the values of the checked variables, using the SNMP Set operation. The values in
the MIB Value fields are sent to the SNMP agent on the device.
Note - SNMPv3: Depending on the WRITE VIEW access settings of the User Account Name
used, there is a possibility that AT-View Plus Device Manager may not be able to set some MIB
values. When this happens, a "No access error." value will be displayed on the affected MIB
Value cells.
Note - SNMPv3: If the User Account Name does not have READ VIEW but has WRITE VIEW
access for a MIB variable, you may still set the value of that variable. However, the new value
will not be displayed on the affected MIB Variable cells.
Note - SNMPv3: Device Manager still allows the user to set values for the following parameters
even if the user has No Write access to these:
System Name
System Contact
System Location
The write attempt will eventually fail and the value, "No access error" will be displayed on the
value column for the said parameters. Additionally, the new values set will be displayed on the
Panel Window, but once the user refreshes the display, the values on the Panel Window will be
reset to the original values set on the device.
6.4.9 Threshold Button
: Set a threshold on the selected variable. The threshold is used to monitor the variable's value.
If the threshold is exceeded, the action configured on the Options menu is executed. To select a
variable, click the MIB Variable field of the target variable. When you click the Threshold
button, the Edit Threshold Item dialog box appears.
Edit Threshold Item dialog box
The MIB Variable field shows the selected variable name.
PN 613-50664-00 Rev B Page 73 of 118