PWR05
AC
The following table describes LEDs on the PWR05 AC power supply unit.
PWR05
DC
The following table describes LEDs on the PWR05 DC power supply unit.
FAN01 The following table describes LEDs on the FAN01 fan-only module.
LED State Description
~
IN
Green AC input voltage is within 90-264 VAC, 47-63Hz.
Off AC input voltage is outside the acceptable range.
OUT
Green DC output voltage is within 12VDC +/- 10%.
Off DC output voltage is outside the acceptable range, or
the Standby switch is Off. If a fault occurs then the
FAULT LED will display and the OUT LED will be Off.
FAULT
Amber A fault has occurred. There is either a fan failure, or the
temperature has exceeded its limit of 70º
C (158º F).
Off No fault conditions detected.
LED State Description
IN
Green DC input voltage is within 40 VDC to 60 VDC.
Off DC input voltage is outside the acceptable range.
OUT
Green DC output voltage is within 12VDC +/- 10%.
Off DC output voltage is outside the acceptable range, or
the Standby switch is Off. If a fault occurs then the
FAULT LED will display and the OUT LED will be Off.
FAULT
Amber A fault has occurred. There is either a fan failure, or the
temperature has exceeded its limit of 70º
C (158º F).
Off No fault conditions detected.
LED State Description
FAULT Red The fan has failed.