Allied Telesis AT-x510DP-52GTX Guia de Instalação

Consulte online ou descarregue Guia de Instalação para Comutadores de rede Allied Telesis AT-x510DP-52GTX. Allied Telesis AT-x510DP-52GTX Installation guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
C613-04066-00 REV B
AT-x510DP-52GTX
Gigabit Ethernet Switch
Installation Guide
S2/52
S1/51
50
49
CONSOLE
2662
x510DP-52GTX
SFP+
FDX HDX COL
1000 LINK ACT 10/100 LINK ACT
3517911131517192123
46810122 16 18 2014
22 24
27 2925 31 33 35 37 39 41 43 45 47
28 30 32 34 3626 40 42 4438
46 48
Vista de página 0
1 2 3 4 5 6 ... 128 129

Resumo do Conteúdo

Página 1 - Installation Guide

C613-04066-00 REV BAT-x510DP-52GTXGigabit Ethernet SwitchInstallation GuideS2/52S1/515049CONSOLE2662x510DP-52GTXSFP+FDX HDX COL1000 LINK ACT

Página 2

Tables10

Página 3 - Industry Canada

Chapter 7: Cabling the Stacking Ports1006. Connect the fiber optic cable to the transceiver, as shown in Figure 64 on page 100. The connector on the c

Página 4 - Translated Safety Statements

101Chapter 8Powering On the StackThis chapter contains the following procedures: “Powering On the Switches Individually” on page 102 “Powering On th

Página 5 - Contents

Chapter 8: Powering On the Stack102Powering On the Switches IndividuallyThis procedure explains how you can control the assignment of the ID numbers o

Página 6

x510DP-52GTX Installation Guide1032. Wait one minute for the switch to initialize its management software.The switch should be displaying the number 1

Página 7

Chapter 8: Powering On the Stack104Powering On the Switches SimultaneouslyIf you want the switches of the stack to use their MAC addresses to automati

Página 8

x510DP-52GTX Installation Guide1052. Wait two or three minutes for the switches to select a master switch and to assign the ID numbers.At this point,

Página 9

Chapter 8: Powering On the Stack106Verifying the StackTo verify stack operations, perform the following procedure:1. Establish a local management sess

Página 10

x510DP-52GTX Installation Guide107Setting thePriority NumbersThis procedure is optional. It explains how to configure the priority settings of the swi

Página 11

Chapter 8: Powering On the Stack1084. Enter the WRITE command to save your change in the configuration file. The switch displays the confirmation prom

Página 12 - Document Conventions

109Chapter 9Cabling the Networking PortsThis chapter contains the following procedures: “Cabling the Twisted Pair Ports” on page 110 “Installing SFP

Página 13 - Contacting Allied Telesis

11PrefaceThis guide contains the installation instructions for the AT-x510DP-52GTX Gigabit Ethernet switch. This preface contains the following sectio

Página 14

Chapter 9: Cabling the Networking Ports110Cabling the Twisted Pair PortsHere are the guidelines to cabling the 10/100/1000Base-T twisted pair ports:

Página 15 - Overview

x510DP-52GTX Installation Guide111 The default duplex mode setting of Auto-Negotiation is not appropriate for ports connected to network devices that

Página 16 - Pair Ports

Chapter 9: Cabling the Networking Ports112Installing SFP and SFP+ TransceiversReview the following guidelines before installing SFP or SFP+ transceive

Página 17

x510DP-52GTX Installation Guide113To install an SFP or SFP+ transceiver, perform the following procedure:1. Remove the dust plug from a transceiver sl

Página 18 - Front and Rear Panels

Chapter 9: Cabling the Networking Ports1144. Slide the transceiver into the slot until it clicks into place, as shown in Figure 70 on page 114.Figure

Página 19 - Management Panel

x510DP-52GTX Installation Guide1156. Verify the position of the handle on the SFP transceiver. If the transceiver is in a top slot, the handle should

Página 20 - Configuration

Chapter 9: Cabling the Networking Ports116

Página 21 - Requirements

117Chapter 10TroubleshootingThis chapter contains suggestions on how to troubleshoot the switch if a problem occurs.NoteFor further assistance, please

Página 22 - SFP+ Slots

Chapter 10: Troubleshooting118— Try connecting the unit to another power source.— Try a different power cord.— Verify that the voltage from the power

Página 23 - Stacking SFP+ Slots

x510DP-52GTX Installation Guide119Problem 4: A twisted pair port on the switch is connected to a network device but the port’s LINK/ACT LED is off.Sol

Página 24 - Chapter 1: Overview

Preface12Document ConventionsThis document uses the following conventions:NoteNotes provide additional information.CautionCautions inform you that per

Página 25 - Twisted Pair

Chapter 10: Troubleshooting120 Verify that the correct type of fiber optic cabling is being used. Verify that the port is connected to the correct f

Página 26

x510DP-52GTX Installation Guide121Problem 8: The Switch ID LED on the front of the switch is flashing the letter “F.”Solutions: One or more of the fol

Página 27 - Stacking Slots

Chapter 10: Troubleshooting122

Página 28

123Appendix ATechnical SpecificationsPhysical SpecificationsEnvironmental SpecificationsTable 7. Physical SpecificationsDimensions(H x W x D)4.4 cm

Página 29

Appendix A: Technical Specifications124Power SpecificationsCertificationsTable 9. Power SpecificationsMaximum Power Consumption110W with two AT-PWR1

Página 30 - USB Port

x510DP-52GTX Installation Guide125RJ-45 Twisted Pair Port PinoutsFigure 74 illustrates the pin layout of the RJ-45 connectors and ports.Figure 74. RJ-

Página 31 - Console Port

Appendix A: Technical Specifications126Table 12 lists the pin signals when a port operating at 1000 Mbps.Table 12. Pin Signals for 1000 MbpsPinout P

Página 32 - Power Supplies

x510DP-52GTX Installation Guide127RJ-45 Style Serial Console Port PinoutsTable 13 lists the pin signals of the RJ-45 style serial Console port.Table 1

Página 33 - AT-PWR100R

Appendix A: Technical Specifications128Fiber Optic Specifications of the AT-StackOP/0.3 and AT-StackOP/9.0 TransceiversTable 14 lists the fiber optic

Página 34

x510DP-52GTX Installation Guide129Table 15 lists the fiber optic port specifications for the AT-StackOP/9.0 transceiver.Table 15. Fiber Optic Port S

Página 35 - Virtual Chassis Stacking

x510DP-52GTX Installation Guide13Contacting Allied TelesisIf you need assistance with this product, you may contact Allied Telesis technical support b

Página 36

Preface14

Página 37

15Chapter 1OverviewThis chapter contains the following sections: “Features” on page 16 “Front and Rear Panels” on page 18 “Management Panel” on pag

Página 38 - Stacking Transceivers

Chapter 1: Overview16FeaturesHere are the features of the AT-x510DP-52GTX switch:10/100/1000Mbps TwistedPair PortsHere are the basic features of the 1

Página 39

x510DP-52GTX Installation Guide17Power SupplyModulesThe AT-x510DP-52GTX switch has two rear slots for hot-swappable power supplies. Power supply optio

Página 40 - Stacking Port Topologies

Chapter 1: Overview18Front and Rear PanelsThe front panel of the AT-x510DP-52GTX switch is shown in Figure 1.Figure 1. Front Panel of the AT-x510DP-52

Página 41

x510DP-52GTX Installation Guide19Management PanelFigure 3 identifies the components in the management panel on the AT-x510DP-52GTX switch.Figure 3. AT

Página 42

Copyright © 2013 Allied Telesis, Inc.All rights reserved. No part of this publication may be reproduced without prior written permission from Allied T

Página 43

Chapter 1: Overview2010/100/1000Base-T Twisted Pair PortsThe switches have 48 10/100/1000Base-T ports.Speed The ports can operate at 10, 100, or 1000

Página 44 - Master Switch

x510DP-52GTX Installation Guide21The MDI and MDI-X settings do not apply when ports are operating at 1000 Mbps.MaximumDistanceThe ports have a maximum

Página 45

Chapter 1: Overview22SFP+ SlotsThe switches have four SFP+ slots that support the following types of SFP 1000Mbps and SFP+ 10Gbps transceivers: 1000B

Página 46 - Stack ID

x510DP-52GTX Installation Guide23Stacking SFP+ SlotsTwo of the four SFP+ slots on the front panel of the switch can be used with stacking transceivers

Página 47 - Beginning the Installation

Chapter 1: Overview24eco-friendly ButtonYou may turn off the port LEDs to conserve electricity when you are not monitoring the switch. The LEDs are to

Página 48 - Reviewing Safety Precautions

x510DP-52GTX Installation Guide25LEDsHere are descriptions of the LEDs.LEDs for theTwisted PairPortsEach twisted pair port has two LEDs that display l

Página 49

Chapter 1: Overview26LEDs for theSFP+ SlotsThe LEDs for the SFP+ slots are located between the slots, as shown in Figure 5. Each SFP+ slot has one LED

Página 50

x510DP-52GTX Installation Guide27LEDs for theStacking SlotsSFP+ slots 51 and 52 may be used as stacking slots to build a VCStack of up to four switche

Página 51

Chapter 1: Overview28Figure 6. Switch ID LEDThe states of the LED when the switch is not operating in the low power mode are shown in Figure 7.Figure

Página 52

x510DP-52GTX Installation Guide29NoteYou can use the SHOW SYSTEM ENVIRONMENT command in the command line interface to identify the source of the probl

Página 53 - Planning a Stack

3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions: FCC Class A, EN55022 Class A, EN61000-3-2, EN61000

Página 54

Chapter 1: Overview30USB PortThe management panel has a USB port. You may use the port to store configuration files on flash drives and to restore the

Página 55 - Unpacking the Switch

x510DP-52GTX Installation Guide31Console PortThe Console port is used to establish a management session with the switch to configure its features and

Página 56

Chapter 1: Overview32Power SuppliesThe AT-x510DP-52GTX switch has two rear slots for hot-swappable power supplies.The switch is supplied with a factor

Página 57 - Supplies

x510DP-52GTX Installation Guide33Figure 9. AT-PWR100R AC Power SupplyFigure 10. AT-PWR250 AC Power SupplyFigure 11. AT-PWR250R DC Power Supply2196DC O

Página 58 - 100-240VAC

Chapter 1: Overview34

Página 59 - Power Supply

35Chapter 2Virtual Chassis StackingThe sections in this chapter are: “Overview” on page 36 “Stacking Slots” on page 37 “Stacking Transceivers” on p

Página 60

Chapter 2: Virtual Chassis Stacking36OverviewVirtual Chassis Stacking (VCStack) allows you to connect up to four switches to form a virtual switch in

Página 61

x510DP-52GTX Installation Guide37Stacking SlotsThe AT-x510DP-52GTX switches come with two stacking slots. The slots are the last two SFP+ slots on the

Página 62

Chapter 2: Virtual Chassis Stacking38Stacking TransceiversYou connect the switches of the VCStack with the stacking transceivers listed in Table 5 and

Página 63

x510DP-52GTX Installation Guide39Here are the transceiver guidelines: The stacking transceivers may only be used in the stacking slots and only with

Página 64 - FDX HDX COL

4Translated Safety StatementsImportant: Safety statements that have the  symbol are translated into multiple languages in the Translated Safety Messa

Página 65 - 3. Turn the switch over

Chapter 2: Virtual Chassis Stacking40Stacking Port TopologiesThe switches of a stack are connected with the S1 and S2 ports and the stacking transceiv

Página 66

x510DP-52GTX Installation Guide41The stack in Figure 14 on page 41 has four switches in the linear topology.Figure 14. Stack of Four Switches in the L

Página 67

Chapter 2: Virtual Chassis Stacking42Figure 15. Stack of Two Switches in the Ring TopologyFigure 16 on page 43 is an example of a stack of four switch

Página 68

x510DP-52GTX Installation Guide43Figure 16. Stack of Four Switches in the Ring TopologyThe topologies are the same in terms of network speed and perfo

Página 69

Chapter 2: Virtual Chassis Stacking44Master and Member SwitchesThe stack has one master switch. The functions of the master switch include: Coordinat

Página 70 - AT-PWR250R

x510DP-52GTX Installation Guide45ID Numbers Each switch must be assigned an ID number. The range is 1 to 4 and the default is 1. The ID numbers are di

Página 71 - Figure 33. Stripped Wire

Chapter 2: Virtual Chassis Stacking46Specifying Ports in the Command Line InterfaceThe command line interface in the management software on the switch

Página 72

47Chapter 3Beginning the InstallationThe chapter contains the following sections: “Reviewing Safety Precautions” on page 48 “Choosing a Site for the

Página 73

Chapter 3: Beginning the Installation48Reviewing Safety PrecautionsPlease review the following safety precautions before beginning the installation pr

Página 74

x510 Series Installation Guide for Virtual Chassis Stacking49WarningFor AC PSUs, power cord is used as a disconnection device. To de-energize equipmen

Página 75

5Preface ...

Página 76

Chapter 3: Beginning the Installation50CautionRisk of explosion if battery is replaced by an incorrect type. Replace only with the same or equivalent

Página 77 - Operations

x510 Series Installation Guide for Virtual Chassis Stacking51WarningReliable earthing of rack-mounted equipment should be maintained. Particular atten

Página 78 - Disabling

Chapter 3: Beginning the Installation52Choosing a Site for the SwitchesObserve these requirements when planning the installation of the switches of a

Página 79

x510 Series Installation Guide for Virtual Chassis Stacking53Planning a StackHere are the guidelines to planning a stack: A stack can have up to four

Página 80

Chapter 3: Beginning the Installation54Table 6. Operating Distances of the AT-StackOP/0.3 TransceiverFiber TypeMinimum Modal Bandwidth @ 850 nm (MHz*k

Página 81 - VCStack Feature

x510 Series Installation Guide for Virtual Chassis Stacking55Unpacking the SwitchFigure 18 lists the items that come with the switch. If any item is m

Página 82

Chapter 3: Beginning the Installation56

Página 83 - Switches

57Chapter 4Installing the Switch and its Power SuppliesThe procedures in this chapter are: “Installing the Power Cord Retaining Clip” on page 58 “In

Página 84

Chapter 4: Installing the Switch and its Power Supplies58Installing the Power Cord Retaining Clip This section applies to AC power supply modules.Perf

Página 85 - Activating VCStack

x510DP-52GTX Installation Guide59Installing Power Supply ModulesOverview The AT-x510DP-52GTX switch has two rear slots for hot-swappable power supplie

Página 86

Contents6Unpacking the Switch ...

Página 87 - Activating

Chapter 4: Installing the Switch and its Power Supplies602. Remove the blank panel from the power supply slots on the rear panel of the switch by unsc

Página 88

x510DP-52GTX Installation Guide61Figure 22. Installing the AT-PWR100R AC Power Supply Module4. Secure the power supply module to the chassis by tighte

Página 89

Chapter 4: Installing the Switch and its Power Supplies625. If you are going to operate the switch with a single power supply module, install the supp

Página 90

x510DP-52GTX Installation Guide63Installing the Switches on a Table or DesktopYou may install the switches on a table or desktop. Here are the guideli

Página 91 - Cabling the Stacking Ports

Chapter 4: Installing the Switch and its Power Supplies64Installing the Switch in an Equipment RackThis procedure requires the following items: Twelv

Página 92

x510DP-52GTX Installation Guide653. Turn the switch over.4. Attach the two rack mount brackets to the sides of the switch using the bracket screws inc

Página 93 - Transceiver

Chapter 4: Installing the Switch and its Power Supplies665. While another person holds the switch in the equipment rack, secure it using standard equi

Página 94 - Release tab

x510DP-52GTX Installation Guide67Connecting AC Power to a Power Supply ModuleTo power on a switch with one or two AC Power Supply Modules, perform the

Página 95

Chapter 4: Installing the Switch and its Power Supplies683. Connect the other end of the power cord to an appropriate AC power outlet. For power speci

Página 96

x510DP-52GTX Installation Guide69Power Wiring to a DC AT-PWR250R-80 Power Supply ModuleThis section describes how to power on a switch with a DC AT-PW

Página 97

7Figure 1: Front Panel of the AT-x510DP-52GTX Switch ...

Página 98 - Figure 61 on page 98

Chapter 4: Installing the Switch and its Power Supplies70as this equipment. Switching or disconnecting devices shall not be in the earthed circuit co

Página 99

x510DP-52GTX Installation Guide714. With a 14-gauge wire-stripping tool, strip the three wires in the tray cable coming from the DC input power source

Página 100

Chapter 4: Installing the Switch and its Power Supplies726. Connect the +48 VDC (RTN) feed wire to the terminal block marked +(plus).7. Connect the -4

Página 101 - Powering On the Stack

x510DP-52GTX Installation Guide73Starting a Local Management SessionThis procedure requires a terminal or a terminal emulator program and the manageme

Página 102

Chapter 4: Installing the Switch and its Power Supplies74Monitoring the Initialization ProcessesIt takes about thirty seconds for the switch to initia

Página 103

x510DP-52GTX Installation Guide75Figure 37. Switch Initialization Messages (Continued)Starting base/loopback... [ OK ]Starting base/sysctl... [ OK ]Re

Página 104

Chapter 4: Installing the Switch and its Power Supplies76Figure 38. Switch Initialization Messages (Continued)Assigning Active Workload to HA processe

Página 105

77Chapter 5Configuring the Switch for Stand-alone OperationsUse this chapter if you wish to operate the switch as a single stand-alone switch, instead

Página 106 - Verifying the Stack

Chapter 5: Configuring the Switch for Stand-alone Operations78Configuring the Switch for Stand-alone OperationsDisablingVCStackAfter the switch has in

Página 107 - Priority Numbers

x510DP-52GTX Installation Guide79NoteThe User Exec mode is the first level in the command mode interface. For complete information on the modes and co

Página 108 - Building configuration

Figures8Figure 50: Moving to the Global Configuration Mode with the CONFIGURE TERMINAL Command...88Figure 51: Activati

Página 109 - Cabling the Networking Ports

Chapter 5: Configuring the Switch for Stand-alone Operations80The ID parameter is the ID number of the switch, displayed on the ID LED. Replace the pa

Página 110

x510DP-52GTX Installation Guide81Confirming theStatus of theVCStack FeatureAnother way to confirm that VCStack is disabled on the switch is by display

Página 111

Chapter 5: Configuring the Switch for Stand-alone Operations82The switch displays the message in Figure 46 on page 82 if VCStack is not disabled, in w

Página 112

x510DP-52GTX Installation Guide83Specifying Ports in the Command Line Interface for Stand-alone SwitchesThe command line interface in the management s

Página 113

Chapter 5: Configuring the Switch for Stand-alone Operations84

Página 114

85Chapter 6Verifying the Status of VCStack and Activating VCStackThe procedures in this chapter are: “Verifying the Status of VCStack” on page 86 “A

Página 115

Chapter 6: Verifying the Status of VCStack and Activating VCStack86Verifying the Status of VCStackBefore you install the stacking transceivers to buil

Página 116

x510DP-52GTX Installation Guide87Activating the VCStack FeaturePerform the following procedure to activate the VCStack feature on switches that displa

Página 117 - Troubleshooting

Chapter 6: Verifying the Status of VCStack and Activating VCStack884. Enter the CONFIGURE TERMINAL command to move to the Global Configuration mode, a

Página 118

x510DP-52GTX Installation Guide898. Restart the switch with the REBOOT command, as shown in Figure 54.Figure 54. Rebooting the Switch with the REBOOT

Página 119

9TablesTable 1: Twisted Pair Cable for the 10/100/1000Base-T Ports ...

Página 120

Chapter 6: Verifying the Status of VCStack and Activating VCStack90

Página 121

91Chapter 7Cabling the Stacking PortsThis chapter contains the following procedures: “Cabling Switches with AT-StackXS/1.0 Transceivers” on page 92

Página 122 - Chapter 10: Troubleshooting

Chapter 7: Cabling the Stacking Ports92Cabling Switches with AT-StackXS/1.0 TransceiversTo cable the switches of the stack with AT-StackXS/1.0 transce

Página 123 - Technical Specifications

x510DP-52GTX Installation Guide933. Remove the dust cap from one end of the transceiver, as shown in Figure 56 on page 93.Figure 56. Removing the Dust

Página 124 - Certifications

Chapter 7: Cabling the Stacking Ports944. Position the transceiver with the release tab on top and slide the transceiver into the slot, as shown in Fi

Página 125

x510DP-52GTX Installation Guide955. Remove the dust cover from the S2 slot in the next switch in the stack as shown in Figure 58 on page 95.NoteThe ca

Página 126

Chapter 7: Cabling the Stacking Ports967. Position the transceiver with the release tab on the bottom and slide it into the slot until it clicks into

Página 127

x510DP-52GTX Installation Guide97Cabling Switches with AT-StackOP/0.3 or AT-StackOP/9.0 TransceiversFor guidelines to cabling the switches with AT-Sta

Página 128 - Transceivers

Chapter 7: Cabling the Stacking Ports983. Slide the transceiver into the slot until it clicks into place, as shown in Figure 61 on page 98.Figure 61.

Página 129

x510DP-52GTX Installation Guide994. Remove the dust cover from the transceiver, as shown in Figure 62 on page 99.Figure 62. Removing the Dust Cover fr

Comentários a estes Manuais

Sem comentários