AT-3714F and AT-3726 Installation Guide
2-7
Setting Up
Terminal for
Local
Management
Using Omega
1. For local management, connect your terminal to the RS232 connector
on the switch’s front panel. Use an RS232 DB9 straight-through cable.
Note
The RS232 is for Setup and Diagnostics only. The cable must be dis-
connected during normal operation to maintain Emissions Compli-
ance.
2. Access your terminal emulator program. Press Return several times
to ensure baud configuration (autobaud).
3. Set your terminal to the following
— 8, data bits
— 1, stop bits
— None, parity
See also Table 2-2, Switch Default Settings.
You are now ready to access the switchs management software,
Omega.
For remote management and further details concerning the Omega
management software, refer to the AT-S20 User’s Guide located at
www.alliedtelesyn.com/manuals.htm.