AT-S65 Management Software User’s Guide
31
3. Enter or change the parameters as desired.
Changes to the parameters take effect immediately on the chassis.
The traps are described in Table 2.
Table 2. SNMP Traps
Trap Description
Chassis Over-Temperature The chassis temperature has exceeded
the set threshold. For information about
setting the chassis temperature threshold,
refer to “Configuring the Chassis
Temperature Threshold” on page 33.
Module Over-Temperature The temperature of a line card has
exceeded the set threshold. For
information about setting the line card
temperature threshold, refer to
“Configuring the Line Card Temperature
Threshold” on page 34.
SFP Over-Temperature The SFP transceiver’s temperature has
exceeded the set threshold. For
information about setting the SFP
temperature threshold, refer to
“Configuring the SFP Temperature
Threshold” on page 35.
SFP Loss of Signal The SFP has been disconnected from the
client port fiber.
Module Loss of Signal The line port has been disconnected from
the line port fiber.
Module Out of Sync The line card is out of synch.
SFP Insertion/Removal An SFP has been inserted into or
removed from a line card.
Module Insertion/Removal A line card has been inserted into or
removed from the system.
RPS Failure A redundant power supply (RPS) has
failed.
RPS Insertion/Removal An RPS has been inserted into or
removed from its slot.
Port Active/Shutdown The port is active or has been shut down.
Fan Failure A failure has occurred in one of the fan
modules.