Allied-telesis AT-S70 Manual do Utilizador Página 271

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 302
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 270
AT-S70 Management Software User’s Guide
271
AT-CV1KSS Line Card DIP Switches
The AT-CV1KSS line card features one set of DIP switches labeled
“SW1”, as shown in Figure 91.
Figure 91. DIP Switch Set on an AT-CV1KSS Line Card
The DIP switches in the SW 1 DIP switch set allow you to set the operating
mode of the line card. For information about the operating modes, refer to
“Configuring the Line Card Operating Mode” on page 67.
Table 9 shows how to enable the operating mode on an AT-CV1KSS line
card by setting the DIP switches in the SW 1 DIP switch set.
“X” means that the DIP switch position can be ON or OFF.
AT-CV1KSS
LK
A
T
S
F
P
SW1
ON
1 2 3 4
4 3 2 1
SW 1 DIP Switch Set
Table 9. SW 1 DIP Switch Set (Operating Mode) for the AT-CV1KSS Line
Card
Operating Mode DIP 1 DIP 2 DIP 3
Smart MissingLink (SML) OFF ON X
MissingLink™ (ML) ON OFF X
Link Test (default) OFF OFF X
Manufacturing Default Settings OFF OFF OFF
Vista de página 270
1 2 ... 266 267 268 269 270 271 272 273 274 275 276 ... 301 302

Comentários a estes Manuais

Sem comentários