AT-S70 Management Software User’s Guide
75
T1 DSX-1(133 to 266ft)
T1 DSX-1(266 to 399ft)
T1 DSX-1(399 to 533ft)
T1 DSX-1(533 to 655ft)
T1 -7.5dB CSU
T1 -15dB CSU
T1 -22.5dB CSU
Transmit All
- All-ones
- Normal (default)
PRBS
- Disabled (default)
- Enabled
Remote Loopback
- Disabled (default)
- Enabled
Local Loopback
- Disabled (default)
- Enabled
If you choose to change the channel’s configuration individually, enter
the info in the following format:
<Item#><space><Channel1#>
The changes will be saved automatically if the EEPROM data was
used.
2. To change your local console settings from “Normal” to “Unframed All
Ones”, type Y to accept the changes, or type N to cancel the changes.
Note
If you wish to undo your changes and return them to the
manufacturing default settings; from the Boot Configuration, select
Boot Data From -> Manufacture Default.
Configuring the
T1/E1 Port
Settings
This section contains the following procedures:
“Configuring the AT-CM70S TDM Port,” next
“Configuring the AT-CM70S UART Setting” on page 80
Configuring the AT-CM70S TDM Port
To change the TDM (time-division multiplexing) port parameters on the
AT-CM70S line card from the AT-CV5M01 Management Card, perform the
following procedure:
1. From the Main Menu, select Module Status and Configuration.