Chapter 15: Building a Stack
296 Section III: Building a Stack with VCStack Plus
Figure 187. SHOW STACK Command
7. Verify the pending ID number change.
Each controller card should now have two ID numbers. The number in
the ID column is the current number of the chassis and the number in
the Pending ID column is the number you just assigned it. The new
number takes effect when you reboot the chassis later in these
instructions.
Do one of the following:
If the Pending ID column is empty or is not displaying the correct
number, repeat the procedure starting with step 3.
If the Pending ID column is displaying the correct ID number,
continue with the next step.
8. Enter the COPY RUNNING-CONFIG command to save your change:
awplus# copy running-config startup-config
9. Continue to the next procedure to set the priority number on the
chassis.
Virtual Chassis Stacking summary information
ID Pending ID MAC address Priority Status Role
1.5 2.5 eccd.6d9e.07e1 128 Ready Active CFC
1.6 2.6 eccd.6d9e.0145 128 Ready Backup Member
Current ID
Number
Pending ID
Number