Allied Telesis AT-IFS802SP/POE Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Comutadores de rede Allied Telesis AT-IFS802SP/POE. Allied Telesis AT-IFS802SP/POE User`s guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 105
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
613-001691 Rev.A
AT-IFS802SP/POE
8x10/100TX POE Layer 2 Managed Industrial Switch
AT-IFS802SP/POE Installation and
User’s Guide
Vista de página 0
1 2 3 4 5 6 ... 104 105

Resumo do Conteúdo

Página 1 - User’s Guide

613-001691 Rev.A AT-IFS802SP/POE 8x10/100TX POE Layer 2 Managed Industrial SwitchAT-IFS802SP/POE Installation andUser’s Guide

Página 2

6 AT-IFS802SP/POE(W)-80 User ManualChapter 1 IntroductionThe 8 10/100TX + 2 10/100/1000T/Mini-GBIC Combo with 8 PoE Injectors Managed Industrial Swit

Página 3 - Industry Canada

96 AT-IFS802SP/POE(W)-80 User ManualTFTP Commands SetAllied Telesis Commands Level Description Examplebackupash:backup_cfgGSavecongurationtoTFTP

Página 4

97AT-IFS802SP/POE(W)-80 User ManualSystemLog, SMTP and Event Commands SetAllied Telesis Commands Level Description Examplesystemlog ip [IP address]GSe

Página 5

98 AT-IFS802SP/POE(W)-80 User Manualno event device-cold-start GDisable cold start event typeswitch(cong)#noeventdevice-cold-startno event authenti

Página 6

99AT-IFS802SP/POE(W)-80 User ManualSNTP Commands SetAllied Telesis Commands Level Description Examplesntp enable G Enable SNTP function switch(cong)#

Página 7

100 AT-IFS802SP/POE(W)-80 User ManualX-ring Commands SetAllied Telesis Commands Level Description Examplering enable G Enable X-ring switch(cong)#rin

Página 8

101AT-IFS802SP/POE(W)-80 User ManualPoE Commands SetAllied Telesis Commands Level Description Examplepoe P EnterPOEconguremode switch#poesystem kn

Página 9

7AT-IFS802SP/POE(W)-80 User ManualNetwork Cable10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E cableEIA/TIA-568 100-ohm (100m)100Base-TX: 2-pair UTP/STP Cat

Página 10 - Chapter 1 Introduction

8 AT-IFS802SP/POE(W)-80 User Manual1.2 Software FeaturesManagement SNMP v1 v2c, v3/ Web/Telnet/CLISNMP MIBRFC 1215 Trap, RFC1213 MIBII, RFC 1157 SNMP

Página 11

9AT-IFS802SP/POE(W)-80 User ManualLogin Security Supports IEEE802.1X Authentication/RADIUSBandwidth ControlSupportingresspacketlterandegresspac

Página 12 - 1.2 Software Features

10 AT-IFS802SP/POE(W)-80 User ManualChapter 2 Hardware DescriptionIn this paragraph, it will describe the Industrial switch’s hardware spec, port, ca

Página 13 - 1.3 Package Contents

11AT-IFS802SP/POE(W)-80 User Manual2.3 Bottom ViewThe bottom panel of the 8 10/100TX w/ X-Ring Managed Industrial Switch has one terminal block conne

Página 14 - 2.1 Physical Dimension

12 AT-IFS802SP/POE(W)-80 User Manual2.4 LED IndicatorsThe diagnostic LEDs that provide real-time information of system and optional status are locate

Página 15 - 2.3 Bottom View

13AT-IFS802SP/POE(W)-80 User ManualChapter 3 Hardware InstallationIn this paragraph, we will describe how to install the 8 10/100TX w/ X-Ring Managed

Página 16 - LED Color Status Meaning

14 AT-IFS802SP/POE(W)-80 User Manual3.2 DIN-Rail MountingThe DIN-Rail is screwed on the industrial switch when out of factory. If the DIN-Rail is not

Página 17 - 3.1 Installation Steps

15AT-IFS802SP/POE(W)-80 User Manual3.3 Wall Mount Plate MountingFollow the steps below to mount the industrial switch with wall mount plate.Remove th

Página 18 - 3.2 DIN-Rail Mounting

Copyright © 2012 Allied Telesis, Inc.All rights reserved. No part of this publication may be reproduced without prior written permission from Allied T

Página 19

16 AT-IFS802SP/POE(W)-80 User Manual3.4 Wiring the Power InputsPlease follow the steps below to insert the power wire.Insert AC or DC power wires int

Página 20 - 3.4 Wiring the Power Inputs

17AT-IFS802SP/POE(W)-80 User Manual3.5 Wiring the Fault Alarm ContactThe fault alarm contacts are in the middle of the terminal block connector as th

Página 21

18 AT-IFS802SP/POE(W)-80 User Manual3.6 CablingUse four twisted-pair, Category 5e or above cabling for RJ-45 port connection. The cable between •the

Página 22 - 3.6 Cabling

19AT-IFS802SP/POE(W)-80 User ManualTo remove the LC connector from the transceiver, please follow the steps shown below:First, press the upper side of

Página 23

20 AT-IFS802SP/POE(W)-80 User ManualChapter 4 Network ApplicationThis chapter provides some sample applications to help user to have more actual idea

Página 24 - 4.1 X-Ring Application

21AT-IFS802SP/POE(W)-80 User Manual4.2 Coupling Ring ApplicationIn the network, it may have more than one X-Ring group. By using the coupling ring fu

Página 25

22 AT-IFS802SP/POE(W)-80 User Manual4.3 Dual Homing ApplicationDual Homing function is to prevent the connection lose from between X-Ring group and u

Página 26 - 4.3 Dual Homing Application

23AT-IFS802SP/POE(W)-80 User ManualChapter 5 Console Management5.1 Connecting to the Console PortThe supplied cable which one end is RS-232 connecto

Página 27 - Chapter 5 Console Management

24 AT-IFS802SP/POE(W)-80 User Manual5.3 Login in the Console Interface When the connection between Switch and PC is ready, turn on the PC and run a t

Página 28 - 5.4 CLI Management

25AT-IFS802SP/POE(W)-80 User Manual5.5 Commands LevelModes Access Method Prompt Exit Method About This Mode1User EXECBegin a session with your switch

Página 29 - 5.5 Commands Level

3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions FCC Class A, CE EN61000-4-2, CE EN61000-4-3, CE EN-

Página 30 - 6.3 System Login

26 AT-IFS802SP/POE(W)-80 User Manual1. Launch the Internet Explorer on the PC2. Key in “http:// “+” the IP address of the switch”, and then Press “E

Página 31 - A p p l y

27AT-IFS802SP/POE(W)-80 User Manual3. The login screen will appear right after4.Keyintheusernameandpassword.Thedefaultusernameandpasswo

Página 32

28 AT-IFS802SP/POE(W)-80 User Manual6.5IPCongurationTheswitchisanetworkdevicewhichneedstobeassignedanIPaddressforbeingidentiedon

Página 33

29AT-IFS802SP/POE(W)-80 User Manual6.6 DHCP ServerDHCPistheabbreviationofDynamicHostCongurationProtocolthatisaprotocolforassigningdyn

Página 34 - 6.6.3 Port and IP Bindings

30 AT-IFS802SP/POE(W)-80 User Manual6.6.2 Client EntriesWhen the DHCP server function is enabled, the system will collect the DHCP client inform

Página 35

31AT-IFS802SP/POE(W)-80 User Manual6.7 TFTPItprovidesthefunctionsallowingtheusertoupdatetheswitchrmwareviatheTrivialFileTransferPro

Página 36 - C l e a r

32 AT-IFS802SP/POE(W)-80 User ManualBackupCongurationinterfaceYoucanbackupthecurrentcongurationfromashROMtotheTFTPserverforthepur

Página 37

33AT-IFS802SP/POE(W)-80 User ManualSyslogCongurationinterfaceSimpleMailTransferProtocol(SMTP)isthestandardforemailtransmissionsacrossth

Página 38

34 AT-IFS802SP/POE(W)-80 User ManualSMTPCongurationinterfaceHaving ticked the Syslog/SMTP checkboxes, the event log/email alert will be sent to the

Página 39

35AT-IFS802SP/POE(W)-80 User ManualPort event selection• : Also, before the drop-down menu items are available, the Syslog Client Modeselectionitem

Página 41

36 AT-IFS802SP/POE(W)-80 User Manual6.9 Fault Relay AlarmThe Fault Relay Alarm function provides the Power Failure and Port Link Down/Broken detectio

Página 42

37AT-IFS802SP/POE(W)-80 User ManualSNTP Client• : Enable/disable SNTP function to get the time from the SNTP server.Daylight Saving Time• : This is

Página 43

38 AT-IFS802SP/POE(W)-80 User ManualSNTP Sever URL• :SettheSNTPserverIPaddress.YoucanassignalocalnetworktimeserverIPaddress or an int

Página 44

39AT-IFS802SP/POE(W)-80 User Manual6.11 IP SecurityIPsecurityfunctionallowstheusertoassign10specicIPaddressesthathavepermissiontoman

Página 45

40 AT-IFS802SP/POE(W)-80 User Manual6.12 User AuthenticationChange web management login user name and password for the management security issue.User

Página 46 - 6.15 Port Trunk

41AT-IFS802SP/POE(W)-80 User ManualPort Statistics interface6.14 Port ControlInPortcontrolyoucancongurethesettingsofeachporttocontrolth

Página 47 - D e l e t e

42 AT-IFS802SP/POE(W)-80 User ManualPort Control interface6.15 Port TrunkPort trunking is the combination of several ports or network cables to expan

Página 48

43AT-IFS802SP/POE(W)-80 User ManualWork ports• :Thiscolumneldallowstheusertotypeinthetotalnumberofactiveportupto four. With LACP st

Página 49

44 AT-IFS802SP/POE(W)-80 User ManualLACP disabled•Having set up the aggregator setting with LACP disabled, you will see the local static trunk

Página 50

45AT-IFS802SP/POE(W)-80 User ManualAssigning 2 ports to a trunk group with LACP disabledStatic Trunking Group informationLACP enabled•Having set up

Página 51

5PrefaceThis manual is the installation and management guide for the AT-IFS802SP/POE 8x10/100TX POE Layer 2 Managed Industrial Switch. The instruction

Página 52

46 AT-IFS802SP/POE(W)-80 User ManualSwitch2congurationSwitch2congurationinterface1. Set System Priority of the trunk group. The default is 1.2

Página 53

47AT-IFS802SP/POE(W)-80 User ManualHavingsetuptheLACPaggregatoronthetabofAggregatorSetting,youcancongurethestateactivityforthemem

Página 54 - 6.18VLANconguration

48 AT-IFS802SP/POE(W)-80 User Manual6.16 Port MirroringThePortmirroringisamethodformonitortrafcinswitchednetworks.Trafcthroughportsc

Página 55

49AT-IFS802SP/POE(W)-80 User Manual6.17 Rate LimitingYoucansetupeveryport’sbandwidthrateandframelimitationtype.Ingress Limit Frame type•

Página 56

50 AT-IFS802SP/POE(W)-80 User Manual6.18VLANcongurationA Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain, which

Página 57 - 802.1QConguration

51AT-IFS802SP/POE(W)-80 User ManualPull down the selection item and focus on • Port Based then press to set the VLAN Operation Mode in Po

Página 58

52 AT-IFS802SP/POE(W)-80 User ManualVLAN—Port Based Edit/Delete interfaceUse to delete the VLAN.•Use to modify group name, VLAN I

Página 59

53AT-IFS802SP/POE(W)-80 User ManualPull down the selection item and focus on • 802.1Q then press to set the VLAN Operation Mode in 802.1Q mode.Enab

Página 60

54 AT-IFS802SP/POE(W)-80 User ManualHybrid Link: A segment which consists of Access and Trunk links. The hybrid port has both the features of access

Página 61 - R e m o ve

55AT-IFS802SP/POE(W)-80 User ManualGroupCongurationinterface> Click .A p p l y6.19 Rapid Spanning TreeThe Rapid Spanning Tree Protoc

Página 62

Preface6

Página 63 - 6.20.3SNMPV3Conguration

56 AT-IFS802SP/POE(W)-80 User Manual[note]FollowtheruleasbelowtoconguretheMAXAge,HelloTime,andForwardDelay Time.2 x (Forward Delay Time

Página 64

57AT-IFS802SP/POE(W)-80 User ManualRSTPPortCongurationinterface6.20SNMPCongurationSimple Network Management Protocol (SNMP) is the protocol de

Página 65

58 AT-IFS802SP/POE(W)-80 User ManualAgent Mode• : Select the SNMP version that you want to use it. And then click to switch to the selected

Página 66

59AT-IFS802SP/POE(W)-80 User ManualConguretheSNMPV3function.Context TableCongureSNMPv3contexttable.Assignthecontextnameofcontexttable

Página 67

60 AT-IFS802SP/POE(W)-80 User ManualAccess TableCongureSNMPv3accesstable.ContextPrex• : set up the context name.Group Name• : set up the grou

Página 68

61AT-IFS802SP/POE(W)-80 User ManualUse a strict priority scheme:Alwaysthehigherqueuewillbeprocessedrst,exceptthehigher queue is empty.Prio

Página 69

62 AT-IFS802SP/POE(W)-80 User ManualSet up the COS priority level. With the drop-down selection item of Priority Type above being selectedasCOSonly

Página 70

63AT-IFS802SP/POE(W)-80 User ManualThe switch support IP multicast, you can enable IGMP protocol on web management’s switch setting advanced page, the

Página 71

64 AT-IFS802SP/POE(W)-80 User ManualEnable Ring• : To enable the X-Ring function, tick the checkbox beside the Enable Ring string label. If this chec

Página 72

65AT-IFS802SP/POE(W)-80 User Manual6.24LLDPCongurationLinkLayerDiscoveryProtocol(LLDP)isdenedintheIEEE802.1AB,itisanemergingstanda

Página 73

3AT-IFS802SP/POE(W)-80 User ManualContentChapter 1 Introduction ...61.1 Hardwa

Página 74 - Multicast Filtering interface

66 AT-IFS802SP/POE(W)-80 User Manual802.1xSystemCongurationinterfaceYoucancongurethe802.1xauthenticationstateforeachport.Thestateprov

Página 75

67AT-IFS802SP/POE(W)-80 User ManualQuiet Period:• Set the period which the port doesn’t try to acquire a supplicant.TX Period• : Set the period

Página 76

68 AT-IFS802SP/POE(W)-80 User ManualAdd the Static MAC AddressYoucanaddstaticMACaddressintheswitchMACtablehere.MAC Address• :EntertheMA

Página 77 - 6.30 System Reboot

69AT-IFS802SP/POE(W)-80 User ManualMAC Address• :EntertheMACaddressthatyouwanttolter.Click .•IfyouwanttodeletetheMACaddress

Página 78 - Troubles shooting

70 AT-IFS802SP/POE(W)-80 User ManualMulticast Filtering interface

Página 79 - RJ-45 Pin Assignments

71AT-IFS802SP/POE(W)-80 User Manual6.27 Power over EthernetThis segment shows the Power over Ethernet function.PoE StatusActual Power Consumption• :

Página 80

72 AT-IFS802SP/POE(W)-80 User ManualPower Limit From• : Check it to decide the power limit method.Classication: When this check box is ticked, the s

Página 81 - Cross over cables schematic

73AT-IFS802SP/POE(W)-80 User Manual6.28 Factory DefaultResetswitchtodefaultconguration.Clicktoresetallcongurationstothedef

Página 82 - RJ-45 Pin Assignments of POE

74 AT-IFS802SP/POE(W)-80 User ManualTroubles shootingVerify that is using the right power cord/adapter (DC 24-48V), please don’t use the power adapter

Página 83 - Appendix B—Command Sets

75AT-IFS802SP/POE(W)-80 User ManualAppendix A—RJ-45 Pin AssignmentThe UTP/STP ports will automatically sense for Fast Ethernet (10Base-T/100Base-TX co

Página 84

4 AT-IFS802SP/POE(W)-80 User Manual6.9 Fault Relay Alarm ...

Página 85 - Port Commands Set

76 AT-IFS802SP/POE(W)-80 User Manual10/100Base-TX Cable Schematic•Thefollowingtwoguresshowthe10/100Base-TXcableschematic.Straight-through ca

Página 86

77AT-IFS802SP/POE(W)-80 User Manual10/100/1000Base-TX Cable Schematic•Straight through cables schematicCross over cables schematic

Página 87 - Trunk Commands Set

78 AT-IFS802SP/POE(W)-80 User ManualRJ-45 Pin Assignments of POEWith 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting data, and pins

Página 88 - VLAN Commands Set

79AT-IFS802SP/POE(W)-80 User ManualAppendix B—Command SetsCommands Set ListUser EXEC Privileged EXEC Globalconguration   VLAN da

Página 89

80 AT-IFS802SP/POE(W)-80 User Manualadmin password[Password]GSpeciesapassword(maximum 10 words)switch(cong)#adminpasswordxxxxxxshow admin PShow

Página 90 - Spanning Tree Commands Set

81AT-IFS802SP/POE(W)-80 User ManualPort Commands SetAllied Telesis Commands Level Description Exampleinterface fastEthernet [Portid] GChoose the port

Página 91

82 AT-IFS802SP/POE(W)-80 User Manualbandwidth out [Value]Set interface output bandwidth. Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps

Página 92 - QOS Commands Set

83AT-IFS802SP/POE(W)-80 User ManualTrunk Commands SetAllied Telesis Commands Level Description Exampleaggregator priority[1~65535]GSet port group syst

Página 93 - IGMP Commands Set

84 AT-IFS802SP/POE(W)-80 User ManualVLAN Commands SetAllied Telesis Commands Level Description Examplevlan database P EnterVLANconguremode switch#

Página 94 - LLDP Commands Set

85AT-IFS802SP/POE(W)-80 User Manualvlan 8021q trunk[PortNumber]access-link untag[UntaggedVID]VAssign a access link for VLAN by trunk groupswitch(vlan)

Página 95 - SNMP Commands Set

5AT-IFS802SP/POE(W)-80 User ManualSystem Commands Set...

Página 96

86 AT-IFS802SP/POE(W)-80 User ManualSpanning Tree Commands SetAllied Telesis Commands Level Description Examplespanning-tree enable G Enable spanning

Página 97 - Port Mirroring Commands Set

87AT-IFS802SP/POE(W)-80 User Manualstp-path-priority[Port Priority] IUse the spanning-tree port-priority interface congurationcommandtocongurea

Página 98 - 802.1x Commands Set

88 AT-IFS802SP/POE(W)-80 User ManualQOS Commands SetAllied Telesis Commands Level Description Exampleqos policy[weighted-fair|strict]GSelect QOS polic

Página 99

89AT-IFS802SP/POE(W)-80 User ManualIGMP Commands SetAllied Telesis Commands Level Description Exampleigmp enable GEnable IGMP snooping functionswitch(

Página 100 - TFTP Commands Set

90 AT-IFS802SP/POE(W)-80 User ManualMac / Filter Table Commands SetAllied Telesis Commands Level Description Examplemac-address-table static hwaddr [M

Página 101

91AT-IFS802SP/POE(W)-80 User ManualSNMP Commands SetAllied Telesis Commands Level Description Examplesnmp system-name [System Name]GSet SNMP agent sys

Página 102

92 AT-IFS802SP/POE(W)-80 User Manualsnmpv3 mibview view [View Name] type [Excluded|Included] sub-oid [OID]GCongurethemibviewtableof SNMPV3 agents

Página 103 - SNTP Commands Set

93AT-IFS802SP/POE(W)-80 User ManualPort Mirroring Commands SetAllied Telesis Commands Level Description Examplemonitor [RX|TX|Both]IConguresourcepo

Página 104 - X-ring Commands Set

94 AT-IFS802SP/POE(W)-80 User Manual802.1x Commands SetAllied Telesis Commands Level Description Example8021x enable GUse the 802.1x global congurati

Página 105 - PoE Commands Set

95AT-IFS802SP/POE(W)-80 User Manual8021x misc maxrequest [number]GUse the 802.1x misc max requestglobalcongurationcommand to set the MAX requests.

Comentários a estes Manuais

Sem comentários