Troubleshooting
112
Figure 96 Diagnostic Window (1 of 5)
You can follow the progress of the test in the right-hand window.
Each test is displayed as it is being performed (e.g. Board Register
Check).
If the test is successful, the word PASSED is displayed at the end of
the line and the next test is started. If there is a problem, the word
Failed is displayed.
If errors are reported, follow the instructions that are provided.
9. Check the configuration and if necessary, repeat the test (see Failure
of a Test).
10. To continue testing, press any key.
11. To quit the diagnostics program, select Exit from the Main Menu.
12. Remove the loopback connector from the port.
13. Re-connect the data cables to the network port.
Caution
For safety reasons, if the adapter is not connected immediately to
the data network, insert the protective plug. Otherwise laser light
may be emitted. Inserting the protective plug is also protects the
port against dust and dirt.