Table 13 lists the general event messages. For the event messages
related to SFP modules in the AT-CM3K0S Line Card, refer to Table 14 on
page 127.
Table 13. General Event Messages
Message Chassis
Classi-
fication
Definition
Auto Copy Succeeded
on linecard n
AT-CV1200
AT-CV1203
AT-CV5000
Report The AT-CM Line Card in slot n
successfully received its configuration
from the master management card and
the master configuration file, through the
autocopy feature. A card installed in a slot
where autocopy is enabled receives its
configuration automatically whenever the
chassis is powered on, the card is reset,
or a replacement card is installed.
n Voltage Failed AT-CV5000 Report The AT-PWR14 or AT-PWR15 Power
Supply Module in the AT-CV5000 Chassis
had an output voltage failure. The variable
n can be 3.3V, 5V, or 12V and signals
which voltage failed.
Clear The AT-PWR14 or AT-PWR15 Power
Supply Module resumed normal
operations or was replaced.
Copper port failure on
remote linecard n.
AT-CV1200
AT-CV1203
AT-CV5000
Report The twisted pair port on a remote AT-CM
Line Card lost its link to its network
device. This message requires remote
peer management.
Clear The twisted pair port on a remote AT-CM
Line Card established a link to its network
device. This messages requires remote
peer management.
CPM Card Reboot AT-CV1200
AT-CV1203
AT-CV5000
Report The AT-CV5M02 Management Card was
reset or powered on.