Resumo do Conteúdo

Página 1 - User’s Guide

613-50617-00 Rev. BManagement SoftwareAT-S70User’s GuideCONVERTEON Media Converter ProductsVersion 1.1.0

Página 2

Preface10Document ConventionsThis document uses the following conventions:NoteNotes provide additional information.CautionCautions inform you that per

Página 3 - Contents

Chapter 8: Operations, Administration, and Maintenance (OAM)100Remote Stable Indicates remote OAM Client acknowledgment of and satisfac

Página 4

AT-S70 Management Software User’s Guide101Loopback State Indicates the current loopback status of the link. This status is determined by a combination

Página 5

Chapter 8: Operations, Administration, and Maintenance (OAM)102DisplayingRemote OAMInformationTo display the status on the remote OAM, perform the fol

Página 6

AT-S70 Management Software User’s Guide103The Show Remote OAM Information Menu, as shown in Figure , is displayed.Displaying OAMStatisticsTo display t

Página 7

Chapter 8: Operations, Administration, and Maintenance (OAM)104The OAM Configuration Menu, as shown in Figure 7 on page 93, is displayed.7. From the O

Página 8

AT-S70 Management Software User’s Guide105OAM Loopback TestThis section contains the procedures on how to manage the OAM loopback test.Enabling orDisa

Página 9 - How This Guide is Organized

Chapter 8: Operations, Administration, and Maintenance (OAM)1068. The OAM Loopback Test Menu, as shown in Figure 41, is displayed.Figure 41. OAM Loopb

Página 10 - Document Conventions

AT-S70 Management Software User’s Guide107The Port Management Menu, as shown in Figure 6 on page 92, is displayed.6. From the Port Management Menu, se

Página 11

Chapter 8: Operations, Administration, and Maintenance (OAM)1088. The OAM Loopback Test Menu, as shown in Figure 41 on page 106, is displayed.9. From

Página 12 - Contacting Allied Telesyn

AT-S70 Management Software User’s Guide109Sending OAM Variable RequestTo send OAM variable request, perform the following procedure:1. From the Main M

Página 13

AT-S70 Managment Software User’s Guide11Where to Find Web-based GuidesThe installation and user guides for all Allied Telesyn products are available i

Página 14 - Overview

110Chapter 9File Downloads and UploadsThis chapter describes how to download AT-S70 software image and configuration updates and contains the followin

Página 15

AT-S70 Management Software User’s Guide111File Uploads and Downloads OverviewThe firmware on the Converteon chassis consists of the following three pa

Página 16 - Local Management Session

Chapter 9: File Downloads and Uploads112File Download GuidelinesThis sections covers the general guidelines that apply to downloading files from both

Página 17 - Telnet Management Session

AT-S70 Management Software User’s Guide113DownloadingFiles from aRemoteManagementSessionGuidelinesThis section contains the procedure for downloading

Página 18 - SNMP Management Session

Chapter 9: File Downloads and Uploads114NoteThere are two different image files used with the Converteon products, the image file used for the chassis

Página 19 - Chapter 2

AT-S70 Management Software User’s Guide115Once the download is complete, it returns you to the HyperTerminal window with the status message as shown i

Página 20 - Using the Terminal Interface

Chapter 9: File Downloads and Uploads116Downloading Software Image FilesThe software image file is provided in a self-extracting compressed file which

Página 21

AT-S70 Management Software User’s Guide117The Administration Menu, as shown in Figure 46, is displayed.Figure 46. Administration MenuAdministration Me

Página 22

Chapter 9: File Downloads and Uploads1183. From the Administration Menu, select Image Download Through TFTP. The following screen is displayed, as sho

Página 23 - Management

AT-S70 Management Software User’s Guide1198. Type Y for to start the download. The following screen is displayed, as shown in Figure 50.Figure 50. TFT

Página 24

Preface12Contacting Allied TelesynThis section provides Allied Telesyn contact information for technical support as well as sales or corporate informa

Página 25

Chapter 9: File Downloads and Uploads1204. Enter Y to start the download process or N to cancel. If you enter Y, the following screen is displayed, as

Página 26 - Saving Your Parameter Changes

AT-S70 Management Software User’s Guide121Downloading Line Card Image FilesDownloadingLine Card ImageFile ThroughXmodemTo download a new line card ima

Página 27 - Chapter 3

Chapter 9: File Downloads and Uploads122A message is displayed, as shown in Figure 55.Figure 55. XModem - Line Card Image Downloading Window8. Begin t

Página 28 - Passwords

AT-S70 Management Software User’s Guide123The following screen is displayed, as shown in Figure 57.Figure 57. TFTP - Enter Line Card Image File Name W

Página 29

Chapter 9: File Downloads and Uploads124The following screen is displayed, as shown in Figure 60.Figure 60. TFTP - Line Card Image Downloading Window1

Página 30 - Console Timeout

AT-S70 Management Software User’s Guide125Downloading and Uploading Configuration FileWhen an AT-CV5M01 CPM is replaced, all the parameter settings sa

Página 31 - Management Access Levels

Chapter 9: File Downloads and Uploads1266. Enter the filename of the configuration file that is to be stored as on the TFTP server.7. Press <Return

Página 32

AT-S70 Management Software User’s Guide127UploadingConfigurationFilesTo upload a new AT-S70 software configuration file onto a chassis from a local ma

Página 33 - Basic Parameters

Chapter 9: File Downloads and Uploads128Once the filename has been specified, the following screen, as shown in Figure 67, is displayed.Figure 67. TFT

Página 34 - Assigning an IP

129Appendix AAT-S70 Default SettingsThe following lists the AT-S70 factory default settings.Settings DefaultIP Address 10.0.0.1Subnet Mask 255.255.252

Página 35 - Naming the

AT-S70 Managment Software User’s Guide13Obtaining Management Software UpdatesNew releases of management software for our managed products are availabl

Página 36 - System Date and

Appendix A: AT-S70 Default Settings130ThresholdMaximum Temperature Threshold 60Settings Default

Página 37 - System Location

AT-S70 Management Software User’s Guide131IndexAactivity log 53displaying 54starting and stopping 54activity log messages 55activity monitor 53AT-CV5M

Página 38 - Default Gateway

Index132OOAMactive and passive mode behaviors 89active mode 88discovery 87local OAM information, displaying 96loopback test 105OAM statistics, display

Página 39

14Chapter 1OverviewThe AT-S70 management software is intended for the Converteon Series chassis. The software is used to monitor and adjust the operat

Página 40 - Disabling DHCP

AT-S70 Management Software User’s Guide15NoteTo prevent unauthorized access, you can assign a password to the management software program that require

Página 41

Chapter 1: Overview16Local Management SessionYou establish a local management session with a Converteon chassis by connecting a terminal or a PC with

Página 42 - Converteon

AT-S70 Management Software User’s Guide17Telnet Management SessionYou can use any management workstation on your network that has the Telnet applicati

Página 43 - Pinging a Remote System

Chapter 1: Overview18SNMP Management SessionThe Converteon chassis can also be remotely managed via Simple Network Management Protocol (SNMP), such as

Página 44

19Chapter 2Starting a Local or Telnet Management SessionThis chapter describes the procedures for starting a local or Telnet management session on a C

Página 45

Copyright © 2005 Allied Telesyn, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied

Página 46

Chapter 2: Starting a Local or Telnet Management Session20Using the Terminal InterfaceIf you are using a DEC VT100 or ANSI (the default) terminal conf

Página 47 - Converteon

AT-S70 Management Software User’s Guide21Local Management SessionOn the AT-CV5M01 CPM card installed in the chassis is a port labelled “console”. You

Página 48 - Data rate (baud rate)

Chapter 2: Starting a Local or Telnet Management Session22NoteThe Converteon chassis has an auto-detect feature on the serial port that automatically

Página 49

AT-S70 Management Software User’s Guide23To make a selection, refer to “Using the Terminal Interface” on page 20.Press <Esc> or select the “Retu

Página 50 - Monitoring System Performance

Chapter 2: Starting a Local or Telnet Management Session24Telnet Management SessionYou can use the Telnet application protocol from a workstation on y

Página 51

AT-S70 Management Software User’s Guide25Quitting from aTelnetManagementSessionTo end a Telnet management session, return to the Main Menu and type Q

Página 52

Chapter 2: Starting a Local or Telnet Management Session26Saving Your Parameter ChangesWhen changes are made to the chassis or to any of the line card

Página 53

27Chapter 3AT-S70 Management Security FeaturesThis chapter describes the security features in the AT-S70 software that can help prevent unauthorized i

Página 54 - Displaying the

Chapter 3: AT-S70 Management Security Features28Manager and Operator PasswordsThe AT-S70 management software has two levels of management access: Mana

Página 55

AT-S70 Management Software User’s Guide292. From the System Configuration Menu, select Omega Options. The Omega Options Menu, as shown in Figure 4, is

Página 57

Chapter 3: AT-S70 Management Security Features30Console TimeoutThis parameter causes the management software to automatically end a management session

Página 58

AT-S70 Management Software User’s Guide31Management Access LevelsThere are two levels of management access in the AT-S70 management software: Manager

Página 59

Chapter 3: AT-S70 Management Security Features32The Omega Options Menu, as shown in Figure 4 on page 29, is displayed.3. Adjust the settings as requir

Página 60

33Chapter 4Basic ParametersThis chapter contains a variety of information and procedures. The is a discussion on when to assign an IP address to a cha

Página 61

Chapter 4: Basic Parameters34When Does a Converteon Chassis Need an IP Address?One of the tasks to building or expanding a network is deciding which o

Página 62

AT-S70 Management Software User’s Guide35Configuring Basic Chassis ParametersThe AT-S70 management software provides options to configure some basic p

Página 63 - Event Logs and Syslog Servers

Chapter 4: Basic Parameters362. From the System Configuration Menu, select the System Name field and enter a unique name for the chassis.The name can

Página 64 - Event Log Overview

AT-S70 Management Software User’s Guide37Configuring theSystem Locationand ContactInformationTo set the system’s location and contact information, per

Página 65 - Working with the Event Log

Chapter 4: Basic Parameters38Configuring theIP Address,Subnet Mask, andDefault GatewayThe procedure in this section explains how to manually assign an

Página 66

AT-S70 Management Software User’s Guide39Configuring theManager IPAddressesYou can specify up to four network management workstations that will receiv

Página 67 - Event Log

Contents4Configuring the Manager IP Addresses...

Página 68 - Syslog Server

Chapter 4: Basic Parameters40Trap community stringThe default setting for this string is “public.”Use these parameters to set the SNMP community strin

Página 69 - Setting Syslog Facility Code

AT-S70 Management Software User’s Guide41To enable or disable the DHCP client software, perform the following procedure:1. From the Main Menu, select

Página 70

Chapter 4: Basic Parameters42Configuring the Chassis Temperature ThresholdYou can set a maximum temperature threshold for the chassis. Whenever a temp

Página 71 - Chapter 7

AT-S70 Management Software User’s Guide43Pinging a Remote SystemYou can instruct the chassis to ping a remote device on your network. This procedure i

Página 72

Chapter 4: Basic Parameters44The Ping window, as shown in Figure 9, is displayed.Figure 9. Ping Window3. Enter the Station IP Address of the end-node

Página 73

AT-S70 Management Software User’s Guide45Viewing the AT-S70 Software Version NumberTo view the latest version of the AT-S70 software release cycle ins

Página 74

Chapter 4: Basic Parameters46Resetting and Restarting the SystemWhen you reset a system, the system is also restarted. Resetting and restarting the sy

Página 75

AT-S70 Management Software User’s Guide47If Yes is selected, the prompt, as shown in Figure 13, is displayed.Figure 13. Resetting Chassis Confirmation

Página 76 - Changing Line Card Settings

Chapter 4: Basic Parameters48Setting the RS-232 Terminal Baud RateThe default settings for the RS-232 port are: Bits per second: 1200 bps to 115200bp

Página 77

AT-S70 Management Software User’s Guide49The Terminal Data Rate Menu, as shown in Figure 15, is displayed listing the baud rates.Figure 15. Terminal D

Página 78 - Card Operating

AT-S70 Management Software User’s Guide5Chapter 9File Downloads and Uploads ...

Página 79

50Chapter 5Monitoring System PerformanceThis chapter describes the features in the AT-S70 for monitoring the performance of the Converteon chassis.Thi

Página 80 - Card Port Duplex

AT-S70 Management Software User’s Guide51Displaying System Status InformationThe AT-S70 management software provides comprehensive status information

Página 81 - Rate Limit

Chapter 5: Monitoring System Performance52StatusIndicates the status of the module or line card. Link (A) and Link (B)Indicates whether there are any

Página 82

AT-S70 Management Software User’s Guide53Using the System Activity MonitorThe AT-S70 management software keeps a list of the chassis SNMP events such

Página 83

Chapter 5: Monitoring System Performance54Starting andStopping theActivity LogTo start or stop the activity log, perform the following procedure:1. Fr

Página 84

AT-S70 Management Software User’s Guide55An example of the Activity Monitor window, as shown in Figure 19, is displayed.Figure 19. Activity Monitor Wi

Página 85

Chapter 5: Monitoring System Performance56Using the System DiagnosticsThe AT-S70 management software provides an option to run diagnostic self-tests o

Página 86 - Maintenance (OAM)

AT-S70 Management Software User’s Guide57The Diagnostic Menu, as shown in Figure 20, is displayed.Figure 20. Diagnostics Menu4. From the Diagnostics M

Página 87

Chapter 5: Monitoring System Performance58The information displayed on this menu is for viewing purposes only. NoteThe Flash PROM and Serial Interface

Página 88

AT-S70 Management Software User’s Guide59Displaying Line Card Image VersionTo view the latest image version of a line card, perform the following proc

Página 89 - OAMPDU Types

6Figure 1. Connecting RS-232 Cable to AT-CV5M01 CPM’s Console Port...21Figure

Página 90 - Extensions

Chapter 5: Monitoring System Performance60The Line Card Module Software Image Version window contains the following information:MAC AddressIndicates t

Página 91 - Configuring OAM Operations

AT-S70 Management Software User’s Guide61Displaying Line Card InformationTo view la line card information, perform the following procedure:1. From the

Página 92

Chapter 5: Monitoring System Performance62The Line Card Module Information window contains the following information:VersionIndicates the software ver

Página 93

63Chapter 6Event Logs and Syslog ServersThis chapter describes how to view and clear the contents of the event logs. The event logs that allow you to

Página 94

Chapter 6: Event Logs and Syslog Servers64Event Log OverviewA managed Converteon media chassis is a complex piece of computer that includes both hardw

Página 95

AT-S70 Management Software User’s Guide65Working with the Event LogThis section contains the following procedures: “Displaying an Event Log” on page

Página 96 - Displaying Local

Chapter 6: Event Logs and Syslog Servers662. From the Administration Menu, select Event Log. The Event Log Menu window is displayed, as shown in Figur

Página 97 - Types” on page 89

AT-S70 Management Software User’s Guide67TimeThe time the event occurred.MessageThe activity the event reported.4. Type the following to scroll throug

Página 98

Chapter 6: Event Logs and Syslog Servers68Working with the Syslog ServerConfiguringSyslog ServerAddressTo specify the IP address of the syslog server,

Página 99

AT-S70 Management Software User’s Guide69Setting Syslog Facility CodeThis feature adds a facility code to the entries when they are sent to the syslog

Página 100

AT-S70 Management Software User’s Guide7Figure 51. XModem - Software Image Download Window119Figure 52. XModem - Software Image Downloading Window12

Página 101

Chapter 6: Event Logs and Syslog Servers701 Various operating systems have been found to utilize Facilities 4, 10, 13 and 14 for security/authorizati

Página 102 - Information

71Chapter 7Working with Line Cards and Other ModulesThis chapter contains the following procedures: “Displaying Basic Line Card Information” on page

Página 103 - Statistics

Chapter 7: Working with Line Cards and Other Modules72Displaying Basic Line Card InformationTo display the status of the modules and line cards in the

Página 104

AT-S70 Management Software User’s Guide73Link (A) and Link (B)Indicates whether there are any active connections between a port and the device connect

Página 105 - OAM Loopback Test

Chapter 7: Working with Line Cards and Other Modules74Displaying Line Card Status InformationThe AT-S70 management software provides detailed informat

Página 106 - Starting or

AT-S70 Management Software User’s Guide75LinkDisplays the status of the link state on the ports. Online - Indicates that there is a valid link. Offl

Página 107 - Clearing

Chapter 7: Working with Line Cards and Other Modules76Changing Line Card SettingsYou can change the following settings to fit your network needs: “Ch

Página 108

AT-S70 Management Software User’s Guide774. Select Port A (fiber - top) or Port B (copper - bottom) of the line card. 5. Press <Return>.The Port

Página 109 - Sending OAM Variable Request

Chapter 7: Working with Line Cards and Other Modules78Changing LineCard OperatingModeTo change the operating mode of a line card, perform the followin

Página 110 - File Downloads and Uploads

AT-S70 Management Software User’s Guide79to an end-node, the media converter shuts down the connection to the other port, thus notifying the end-node

Página 111

8Table 1. Menu Selection Options ...

Página 112 - File Download Guidelines

Chapter 7: Working with Line Cards and Other Modules80Changing LineCard Port DuplexModeTo change the duplex mode of a port on the line card, perform t

Página 113

AT-S70 Management Software User’s Guide81Configuring theLine CardIngress/EgressRate LimitThere are certain rules that a chassis follows as it receives

Página 114

Chapter 7: Working with Line Cards and Other Modules82The Port Ingress Rate Menu, as shown in Figure 32, or the Port Egress Rate Menu, as shown in Fig

Página 115

AT-S70 Management Software User’s Guide83Displaying AT-CV5M01 CPM Card Status InformationThe following procedure allows you to view and change the par

Página 116 - File Through

Chapter 7: Working with Line Cards and Other Modules84SpeedDisplays the operating speed of the ports. Possible values are Auto, 10M, 100M, or 1000M.Mo

Página 117

AT-S70 Management Software User’s Guide85Displaying LED Interface Card Status InformationThe following procedure allows you to view the LED status dis

Página 118

86Chapter 8Operations, Administration, and Maintenance (OAM)This chapter describes the Operations, Administration, and Maintenance (OAM) feature, whic

Página 119

AT-S70 Management Software User’s Guide87OverviewThe Operation, Administration and Maintenance (OAM) is a group of functions that provides tools and u

Página 120 - Ready to download

Chapter 8: Operations, Administration, and Maintenance (OAM)88One important aspect of the IEEE 802.3ah OAM spec is that an OAM entity may be in either

Página 121 - Line Card Image

AT-S70 Management Software User’s Guide89Table 3 lists the OAM Active and OAM Passive mode behaviors. OAMPDU TypesTwo Ethernet ports use OAMPDU to exc

Página 122

9PrefaceThis user’s guide contains instructions on how to configure a Converteon chassis using the menu and interfaces of the AT-S70 management softwa

Página 123

Chapter 8: Operations, Administration, and Maintenance (OAM)90 Organizational Specific OAMPDUs – Organizations Specific OAMPDUs are used to define ev

Página 124

AT-S70 Management Software User’s Guide91Configuring OAM OperationsTo configure the OAM operations, perform the following procedure:1. From the Main M

Página 125 - Configuration

Chapter 8: Operations, Administration, and Maintenance (OAM)92Figure 37. Module Configuration Menu (Line Card)4. Select the port that you want to conf

Página 126

AT-S70 Management Software User’s Guide93The OAM Configuration Menu, as shown in Figure 39, is displayed.Figure 39. OAM Configuration Menu7. From the

Página 127 - Uploading

Chapter 8: Operations, Administration, and Maintenance (OAM)94Admin StateIndicates the current status of the OAM administration. Possible values are:

Página 128

AT-S70 Management Software User’s Guide95Variable Retrieval SupportIndicates whether or not the chassis supports sending Variable Response OAMPDUs. Y

Página 129 - AT-S70 Default Settings

Chapter 8: Operations, Administration, and Maintenance (OAM)96Displaying OAM Information and StatisticsThis section contains the procedures on how to

Página 130 - Settings Default

AT-S70 Management Software User’s Guide97The Show Local OAM Information Menu, as shown in Figure , is displayed.For more information on the OAMPDU typ

Página 131

Chapter 8: Operations, Administration, and Maintenance (OAM)98The Show Local OAM Information Menu items and options are described below:Line Card Oper

Página 132

AT-S70 Management Software User’s Guide99Mux StateGoverns the flow of frames from the MAC Client through the multiplexer function. Possible values are