613-001764 Rev. B
x510 Series
Gigabit Ethernet Switches
AT-x510-28GTX
AT-x510-28GPX
AT-x510-28GSX
AT-x510-52GTX
AT-x510-52GPX
Installation Guide for Stand-alone
Switches
Vista de página 0
1 2 3 4 5 6 ... 89 90

Resumo do Conteúdo

Página 1 - Switches

613-001764 Rev. Bx510 SeriesGigabit Ethernet Switches AT-x510-28GTX AT-x510-28GPX AT-x510-28GSX AT-x510-52GTX AT-x510-52GPXInstallation Guide for

Página 2

Tables10

Página 3 - Industry Canada

11PrefaceThis guide contains the installation instructions for the x510 Series of Layer 2+ and Basic Layer 3, Gigabit Ethernet switches. This preface

Página 4 - Translated Safety Statements

Preface12Document ConventionsThis document uses the following conventions:NoteNotes provide additional information.CautionCautions inform you that per

Página 5 - Contents

x510 Series Installation Guide for Stand-alone Switches13Contacting Allied TelesisIf you need assistance with this product, you may contact Allied Te

Página 6

Preface14

Página 7

15Chapter 1OverviewThis chapter contains the following sections: “Features” on page 16 “Front and Back Panels” on page 19 “Management Panel” on pag

Página 8

Chapter 1: Overview16FeaturesHere are the switches and their features:x510 Models Here are the x510 Series switches: AT-x510-28GTX AT-x510-28GPX AT

Página 9

x510 Series Installation Guide for Stand-alone Switches17 Supports single-port BiDi 1000Base-LX SFP transceivers Supports 1000Base-ZX SFP transceive

Página 10

Chapter 1: Overview18LEDs Here are the port LEDs: Link/activity and duplex mode LEDs for the twisted pair ports on non-PoE switches Link/activity an

Página 11 - ™), refer to the x510 Series

x510 Series Installation Guide for Stand-alone Switches19Front and Back PanelsThe front panels of the x510 Series switches are shown in Figure 1 and F

Página 12 - Document Conventions

Copyright  2013 Allied Telesis, Inc.All rights reserved. No part of this publication may be reproduced without prior written permission from Allied T

Página 13 - Contacting Allied Telesis

Chapter 1: Overview20Figure 2. Front Panels of the AT-x510-28GSX, AT-x510-52GTX, and AT-x510-52GPX SwitchesAT-x510-52GPXAT-x510-52GTXSFP+ SlotsManagem

Página 14

x510 Series Installation Guide for Stand-alone Switches21Figure 3 shows the back panel of the AT-x510-28GTX, AT-x510-52GTX, and AT-x510-28GSX Switches

Página 15 - Overview

Chapter 1: Overview22Management PanelFigure 5 identifies the components in the management panels on the x510 Series switches.Figure 5. x510 Series Man

Página 16 - Features

x510 Series Installation Guide for Stand-alone Switches2310/100/1000Base-T Twisted Pair PortsThe switches have 24 or 48 10/100/1000Base-T ports.Speed

Página 17

Chapter 1: Overview24The MDI and MDI-X settings do not apply when ports are operating at 1000 Mbps.MaximumDistanceThe ports have a maximum operating d

Página 18

x510 Series Installation Guide for Stand-alone Switches25Power Over EthernetThe AT-x510-28GPX and AT-x510-52GPX Switches feature Power over Ethernet (

Página 19 - Front and Back Panels

Chapter 1: Overview26CableRequirementsThe cable requirements for ports operating at 10 or 100Mbps are given in Table 3.Table 2. IEEE Powered Device Cl

Página 20

x510 Series Installation Guide for Stand-alone Switches27The cable requirements for ports operating at 1000Mbps are given in Table 4.Power Budget The

Página 21

Chapter 1: Overview28simultaneously as long as the total is below its power budget. If the total exceeds the available power budget, you should consid

Página 22 - Management Panel

x510 Series Installation Guide for Stand-alone Switches29of the power supplies fail or lose power. If you limit the power requirements of the critical

Página 23 - Configuration

3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions: FCC Class A, EN55022 Class A, EN61000-3-2, EN61000

Página 24 - Requirements

Chapter 1: Overview30SFP+ SlotsThe switches have four SFP+ slots that support the following types of SFP 1000Mbps and SFP+ 10Gbps transceivers: 1000B

Página 25 - Power Over Ethernet

x510 Series Installation Guide for Stand-alone Switches31Stacking SFP+ SlotsTwo of the four SFP+ slots on the front panel of the switch can be used wi

Página 26

Chapter 1: Overview32eco-friendly ButtonThe eco-friendly button on the front panel of the switch is used to toggle the port LEDs on or off. You might

Página 27

x510 Series Installation Guide for Stand-alone Switches33LEDsHere are descriptions of the LEDs.LEDs for theTwisted PairPortsThe twisted pair ports on

Página 28 - Prioritization

Chapter 1: Overview34The twisted pair ports on the AT-x510-28GPX and AT-x510-52GPX Switches have two LEDs that display link, activity and PoE informat

Página 29 - Implementation

x510 Series Installation Guide for Stand-alone Switches35Figure 7. LEDs for the 10/100/1000Base-T Ports on the AT-x510-28GPX and AT-x510-52GPX Switche

Página 30 - SFP+ Slots

Chapter 1: Overview36LEDs for the SFPSlotsThe LEDs for the SFP slots on the AT-x510-28GSX Switch are located between the slots, as shown in Figure 9.

Página 31 - Stacking SFP+ Slots

x510 Series Installation Guide for Stand-alone Switches37The LEDs are described in Table 8.LEDs for theSFP+ SlotsThe LEDs for the SFP+ slots are locat

Página 32 - Chapter 1: Overview

Chapter 1: Overview38LEDs for theStacking SlotsSFP+ slots 27 and 28 on the 28-port switches and slots 51 and 52 on the 52-port switches may be used as

Página 33 - Twisted Pair

x510 Series Installation Guide for Stand-alone Switches39Figure 10. Switch ID LEDThe states of the LED when the switch is not operating in the low pow

Página 34

4Translated Safety StatementsImportant: Safety statements that have the  symbol are translated into multiple languages in the Translated Safety State

Página 35

Chapter 1: Overview40NoteYou can use the SHOW SYSTEM ENVIRONMENT command in the command line interface to identify the source of the problem.The state

Página 36 - LEDs for the SFP

x510 Series Installation Guide for Stand-alone Switches41USB PortThe management panel has a USB port. You may use the port to store configuration file

Página 37

Chapter 1: Overview42Console PortThe Console port is used to establish a management session with the switch to configure its features and parameter se

Página 38 - Stacking Slots

x510 Series Installation Guide for Stand-alone Switches43Power SuppliesThe x510 Series switches have two AC power supplies with separate AC connectors

Página 39 - Switch ID LED

Chapter 1: Overview44

Página 40

45Chapter 2Beginning the InstallationThe chapter contains the following sections: “Reviewing Safety Precautions” on page 46 “Choosing a Site for the

Página 41 - USB Port

Chapter 2: Beginning the Installation46Reviewing Safety PrecautionsPlease review the following safety precautions before beginning the installation pr

Página 42 - Console Port

x510 Series Installation Guide for Stand-alone Switches47WarningClass I Equipment. This equipment must be earthed. The power plug must be connected to

Página 43 - Power Supplies

Chapter 2: Beginning the Installation48CautionRisk of explosion if battery is replaced by an incorrect type. Replace only with the same or equivalent

Página 44

x510 Series Installation Guide for Stand-alone Switches49WarningReliable earthing of rack-mounted equipment should be maintained. Particular attention

Página 46 - Reviewing Safety Precautions

Chapter 2: Beginning the Installation50Choosing a Site for the SwitchObserve these requirements when planning the installation of the switch. If you

Página 47

x510 Series Installation Guide for Stand-alone Switches51Unpacking the SwitchFigure 13 lists the items that come with the switch. If any item is missi

Página 48

Chapter 2: Beginning the Installation52

Página 49

53Chapter 3Installing the Switch on a Table or in an Equipment RackThe procedures in this chapter are: “Installing the Switch on a Table or Desktop”

Página 50

Chapter 3: Installing the Switch on a Table or in an Equipment Rack54Installing the Switch on a Table or DesktopYou may install the switch on a table

Página 51 - Unpacking the Switch

x510 Series Installation Guide for Stand-alone Switches55Installing the Switch in an Equipment RackThis procedure requires the following items: Eight

Página 52

Chapter 3: Installing the Switch on a Table or in an Equipment Rack563. Turn the switch over.4. Attach the two rack mount brackets to the sides of the

Página 53 - Equipment Rack

x510 Series Installation Guide for Stand-alone Switches57Figure 17. Attaching the Equipment Rack Brackets (Continued)5. While another person holds the

Página 54

Chapter 3: Installing the Switch on a Table or in an Equipment Rack58

Página 55

59Chapter 4Cabling the Networking PortsThis chapter contains the following procedures: “Cabling the Twisted Pair Ports” on page 60 “Installing SFP a

Página 56 - 3. Turn the switch over

Contents6Chapter 3: Installing the Switch on a Table or in an Equipment Rack ...

Página 57

Chapter 4: Cabling the Networking Ports60Cabling the Twisted Pair PortsHere are the guidelines to cabling the 10/100/1000Base-T twisted pair ports: T

Página 58

x510 Series Installation Guide for Stand-alone Switches61 The default duplex mode setting of Auto-Negotiation is not appropriate for ports connected

Página 59 - Cabling the Networking Ports

Chapter 4: Cabling the Networking Ports62Installing SFP and SFP+ TransceiversThis section contains guidelines and procedures for installing SFP and SF

Página 60

x510 Series Installation Guide for Stand-alone Switches63Installing SFPModules in theAT-x510-28GSXSwitchTo install SFP transceivers in slots 1 to 24 o

Página 61

Chapter 4: Cabling the Networking Ports64Figure 20. Installing an SFP TransceiverNoteIf you are ready to attach the fiber optic cable to the transceiv

Página 62

x510 Series Installation Guide for Stand-alone Switches65Figure 22. Positioning the SFP Handle in the Upright Position7. Connect the fiber optic cable

Página 63 - AT-x510-28GSX

Chapter 4: Cabling the Networking Ports66Installing SFPand SFP+ModulesTo install SFP and SFP+ transceivers in slots 27 and 28 of the 28-port switches

Página 64

x510 Series Installation Guide for Stand-alone Switches67Figure 25. Installing an SFP or SFP+ TransceiverNoteIf you are ready to attach the fiber opti

Página 65 - SFP Handle

Chapter 4: Cabling the Networking Ports686. Verify the position of the handle on the SFP transceiver. If the transceiver is in a top slot, the handle

Página 66

69Chapter 5Powering On the SwitchThis chapter contains the following procedures: “Powering On the Switch” on page 70 “Configuring the Switch for Sta

Página 67

7Figure 1: Front Panels of the AT-x510-28GTX and AT-x510-28GPX Switches ...19Figure 2:

Página 68

Chapter 5: Powering On the Switch70Powering On the SwitchTo power on the switch, connect the power cords to the connectors on the back panels and to t

Página 69 - Powering On the Switch

x510 Series Installation Guide for Stand-alone Switches71Monitoring theInitializationProcessesIt takes about thirty seconds for the switch to initiali

Página 70

Chapter 5: Powering On the Switch72Figure 31. Switch Initialization Messages (Continued)Starting base/loopback... [ OK ]Starting base/poe_done... [ OK

Página 71 - Processes

x510 Series Installation Guide for Stand-alone Switches73Figure 32. Switch Initialization Messages (Continued)After the switch has initialized its man

Página 72

Chapter 5: Powering On the Switch74Configuring the Switch for Stand-alone OperationsAfter the switch has initialized its management software, examine

Página 73

x510 Series Installation Guide for Stand-alone Switches75Figure 33. Connecting the Management Cable to the Console Port2. Connect the other end of the

Página 74 - Management

Chapter 5: Powering On the Switch76DisablingVCStackTo disable the VCStack feature to use the switch as stand-alone unit, perform the following procedu

Página 75

x510 Series Installation Guide for Stand-alone Switches77 If the Operational Status is “Standalone Unit,” as shown in Figure 35 on page 76, the VCSta

Página 76 - Disabling

Chapter 5: Powering On the Switch78Figure 39. Saving the Changes with the WRITE Command9. Enter the REBOOT command to reboot the switch.10. At the con

Página 77

x510 Series Installation Guide for Stand-alone Switches79Figure 40. Status of a Stacking Slot When VCStack is DisabledThe switch displays the message

Página 79

Chapter 5: Powering On the Switch80Specifying Ports in the Command Line Interface for Stand-alone SwitchesThe command line interface in the management

Página 80

81Chapter 6TroubleshootingThis chapter contains suggestions on how to troubleshoot the switch if a problem occurs.NoteFor further assistance, please c

Página 81 - Troubleshooting

Chapter 6: Troubleshooting82 Try connecting another network device to the twisted pair port with a different cable. If the twisted pair port is able

Página 82

x510 Series Installation Guide for Stand-alone Switches83 Test the attenuation of both directions on the fiber optic cable with a fiber optic tester

Página 83

Chapter 6: Troubleshooting84Problem 8: The AT-x510-28GPX or AT-x510-52GPX Switch is not providing power to a PoE device.Solutions: Try the following:

Página 84

85Appendix ATechnical SpecificationsPhysical SpecificationsDimensions (H x W x D)WeightsVentilationTable 11. Product DimensionsAT-x510-28GTX 4.4 cm x

Página 85 - Technical Specifications

Appendix A: Technical Specifications86Environmental SpecificationsPower SpecificationsMaximum Power ConsumptionInput VoltagesTable 14. Environmental S

Página 86 - Power Specifications

x510 Series Installation Guide for Stand-alone Switches87CertificationsRJ-45 Twisted Pair Port PinoutsFigure 43 illustrates the pin layout of the RJ-4

Página 87 - Certifications

Appendix A: Technical Specifications88Table 19 lists the pin signals when a port operating at 1000 Mbps.RJ-45 Style Serial Console Port PinoutsTable 2

Página 88

x510 Series Installation Guide for Stand-alone Switches893 Transmit Data4 Ground5 Ground6 Receive Data7 Looped to pin 2.8 Looped to pin 1.Table 20. RJ

Página 89

9TablesTable 1: Twisted Pair Cable for the 10/100/1000Base-T Ports ......

Página 90

Appendix A: Technical Specifications90

Comentários a estes Manuais

Sem comentários