Allied-telesis x510 Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware de computador Allied-telesis x510 Series. Allied Telesis x510 Series User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
613-001780 Rev. B
x510 Series
Gigabit Ethernet Switches
AT-x510-28GTX
AT-x510-28GPX
AT-x510-28GSX
AT-x510-52GTX
AT-x510-52GPX
Installation Guide for Virtual Chassis
Stacking
Vista de página 0
1 2 3 4 5 6 ... 121 122

Resumo do Conteúdo

Página 1 - Stacking

613-001780 Rev. Bx510 SeriesGigabit Ethernet Switches AT-x510-28GTX AT-x510-28GPX AT-x510-28GSX AT-x510-52GTX AT-x510-52GPXInstallation Guide for

Página 2

Tables10

Página 3 - Industry Canada

Chapter 7: Powering On the Stack100Figure 50. Switch Initialization Messages (Continued)Received event network.activatedLoading default configurationW

Página 4 - Translated Safety Statements

101Chapter 8Cabling the Networking PortsThis chapter contains the following procedures: “Cabling the Twisted Pair Ports” on page 102 “Installing SFP

Página 5 - Contents

Chapter 8: Cabling the Networking Ports102Cabling the Twisted Pair PortsHere are the guidelines to cabling the 10/100/1000Base-T twisted pair ports:

Página 6

x510 Series Installation Guide for Virtual Chassis Stacking103 The default duplex mode setting of Auto-Negotiation is not appropriate for ports conne

Página 7

Chapter 8: Cabling the Networking Ports104Installing SFP and SFP+ TransceiversThis section contains guidelines and procedures for installing SFP and S

Página 8

x510 Series Installation Guide for Virtual Chassis Stacking105Installing SFPModules in theAT-x510-28GSXSwitchTo install SFP transceivers in slots 1 to

Página 9

Chapter 8: Cabling the Networking Ports106Figure 52. Installing an SFP TransceiverNoteIf you are ready to attach the fiber optic cable to the transcei

Página 10

x510 Series Installation Guide for Virtual Chassis Stacking107Figure 54. Positioning the SFP Handle in the Upright Position7. Connect the fiber optic

Página 11 - ™), For

Chapter 8: Cabling the Networking Ports108Installing SFPand SFP+ModulesTo install SFP and SFP+ transceivers in slots 27 and 28 of the 28-port switches

Página 12 - Document Conventions

x510 Series Installation Guide for Virtual Chassis Stacking109Figure 57. Installing an SFP or SFP+ TransceiverNoteIf you are ready to attach the fiber

Página 13 - Contacting Allied Telesis

11PrefaceThis guide contains the installation instructions for the x510 Series of Layer 2+ and Basic Layer 3, Gigabit Ethernet switches. This preface

Página 14

Chapter 8: Cabling the Networking Ports110Figure 59. Positioning the SFP or SFP+ Handle in the Upright Position7. Connect the fiber optic cable to the

Página 15 - Overview

111Chapter 9TroubleshootingThis chapter contains suggestions on how to troubleshoot the switch if a problem occurs.NoteFor further assistance, please

Página 16 - Features

Chapter 9: Troubleshooting112 Verify that VCStack is activated on the switches. For instructions, refer to Chapter 5, “Verifying the Status of VCStac

Página 17

x510 Series Installation Guide for Virtual Chassis Stacking113 If you are using SFP+ slots 27 or 28 on a 28-port switch or slots 51 and 52 on a 52-po

Página 18

Chapter 9: Troubleshooting114 Use the SHOW SYSTEM ENVIRONMENT command in the Privileged Exec mode to verify that the fan is operating correctly. Ver

Página 19 - Front and Back Panels

115Appendix ATechnical SpecificationsPhysical SpecificationsDimensions (H x W x D)WeightsVentilationTable 12. Product DimensionsAT-x510-28GTX 4.4 cm x

Página 20

Appendix A: Technical Specifications116Environmental SpecificationsPower SpecificationsMaximum Power ConsumptionInput VoltagesTable 15. Environmental

Página 21

x510 Series Installation Guide for Virtual Chassis Stacking117CertificationsRJ-45 Twisted Pair Port PinoutsFigure 61 illustrates the pin layout of the

Página 22 - Management Panel

Appendix A: Technical Specifications118Table 20 lists the pin signals when a port operating at 1000 Mbps.3RX+ TX+4 Not used Not used5 Not used Not use

Página 23 - Configuration

x510 Series Installation Guide for Virtual Chassis Stacking119RJ-45 Style Serial Console Port PinoutsTable 21 lists the pin signals of the RJ-45 style

Página 24 - Requirements

Preface12Document ConventionsThis document uses the following conventions:NoteNotes provide additional information.CautionCautions inform you that per

Página 25 - Power Over Ethernet

Appendix A: Technical Specifications120Fiber Optic Specifications of the AT-StackOP/0.3 and AT-StackOP/9.0 TransceiversTable 22 lists the fiber optic

Página 26

x510 Series Installation Guide for Virtual Chassis Stacking121TransmitterWavelength 1310 nmOutput Optical Power -8.2 dBm min.+0.5 dBm max.ReceiverWave

Página 27

Appendix A: Technical Specifications122

Página 28 - Prioritization

x510 Series Installation Guide for Virtual Chassis Stacking13Contacting Allied TelesisIf you need assistance with this product, you may contact Allie

Página 30 - SFP+ Slots

15Chapter 1OverviewThis chapter contains the following sections: “Features” on page 16 “Front and Back Panels” on page 19 “Management Panel” on pag

Página 31 - Stacking SFP+ Slots

Chapter 1: Overview16FeaturesHere are the switches and their features:x510 Models Here are the x510 Series switches: AT-x510-28GTX AT-x510-28GPX AT

Página 32 - Chapter 1: Overview

x510 Series Installation Guide for Virtual Chassis Stacking17 Supports single-port BiDi 1000Base-LX SFP transceivers Supports 1000Base-ZX SFP transc

Página 33 - Twisted Pair

Chapter 1: Overview18 AT-StackOP/9.0 Fiber Optic Transceiver - 9 kilometersLEDs Here are the port LEDs: Link/activity and duplex mode LEDs for the t

Página 34

x510 Series Installation Guide for Virtual Chassis Stacking19Front and Back PanelsThe front panels of the x510 Series switches are shown in Figure 1 a

Página 35

Copyright  2013 Allied Telesis, Inc.All rights reserved. No part of this publication may be reproduced without prior written permission from Allied T

Página 36 - LEDs for the SFP

Chapter 1: Overview20Figure 2. Front Panels of the AT-x510-28GSX, AT-x510-52GTX, and AT-x510-52GPX SwitchesAT-x510-52GPXAT-x510-52GTXSFP+ SlotsManagem

Página 37

x510 Series Installation Guide for Virtual Chassis Stacking21Figure 3 shows the back panel of the AT-x510-28GTX, AT-x510-52GTX, and AT-x510-28GSX Swit

Página 38 - Stacking Slots

Chapter 1: Overview22Management PanelFigure 5 identifies the components in the management panel on the x510 Series switches.Figure 5. x510 Series Mana

Página 39 - Switch ID LED

x510 Series Installation Guide for Virtual Chassis Stacking2310/100/1000Base-T Twisted Pair PortsThe switches have 24 or 48 10/100/1000Base-T ports.Sp

Página 40

Chapter 1: Overview24The MDI and MDI-X settings do not apply when ports are operating at 1000 Mbps.MaximumDistanceThe ports have a maximum operating d

Página 41 - USB Port

x510 Series Installation Guide for Virtual Chassis Stacking25Power Over EthernetThe AT-x510-28GPX and AT-x510-52GPX Switches feature Power over Ethern

Página 42 - Console Port

Chapter 1: Overview26CableRequirementsThe cable requirements for ports operating at 10 or 100Mbps are given in Table 3.Table 2. IEEE Powered Device Cl

Página 43 - Power Supplies

x510 Series Installation Guide for Virtual Chassis Stacking27The cable requirements for ports operating at 1000Mbps are given in Table 4.Power Budget

Página 44

Chapter 1: Overview28simultaneously as long as the total is below its power budget. If the total exceeds the available power budget, you should consid

Página 45 - Virtual Chassis Stacking

x510 Series Installation Guide for Virtual Chassis Stacking29of the power supplies fail or lose power. If you limit the power requirements of the crit

Página 46

3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions: FCC Class A, EN55022 Class A, EN61000-3-2, EN61000

Página 47

Chapter 1: Overview30SFP+ SlotsThe switches have four SFP+ slots that support the following types of SFP 1000Mbps and SFP+ 10Gbps transceivers: 1000B

Página 48 - Stacking Transceivers

x510 Series Installation Guide for Virtual Chassis Stacking31Stacking SFP+ SlotsTwo of the four SFP+ slots on the front panel of the switch can be use

Página 49

Chapter 1: Overview32eco-friendly ButtonYou may turn off the port LEDs to conserve electricity when you are not monitoring the switch. The LEDs are to

Página 50 - Stacking Port Topologies

x510 Series Installation Guide for Virtual Chassis Stacking33LEDsHere are descriptions of the LEDs.LEDs for theTwisted PairPortsEach twisted pair port

Página 51

Chapter 1: Overview34The twisted pair ports on the AT-x510-28GPX and AT-x510-52GPX Switches have two LEDs that display link, activity and PoE informat

Página 52

x510 Series Installation Guide for Virtual Chassis Stacking35Figure 7. LEDs for the 10/100/1000Base-T Ports on the AT-x510-28GPX and AT-x510-52GPX Swi

Página 53

Chapter 1: Overview36LEDs for the SFPSlotsThe LEDs for the SFP slots on the AT-x510-28GSX Switch are located between the slots, as shown in Figure 8.

Página 54 - Master and Member Switches

x510 Series Installation Guide for Virtual Chassis Stacking37The LEDs are described in Table 7.LEDs for theSFP+ SlotsThe LEDs for the SFP+ slots are l

Página 55

Chapter 1: Overview38LEDs for theStacking SlotsSFP+ slots 27 and 28 on the 28-port switches and slots 51 and 52 on the 52-port switches may be used as

Página 56 - Stack ID

x510 Series Installation Guide for Virtual Chassis Stacking39Switch ID LED The Switch ID LED, shown in Figure 10, displays the ID number of the switch

Página 57 - Beginning the Installation

4Translated Safety StatementsImportant: Safety statements that have the  symbol are translated into multiple languages in the Translated Safety State

Página 58 - Reviewing Safety Precautions

Chapter 1: Overview40The switch displays the letter “F” for fault on the ID LED if it encounters one of the following problems: A cooling fan has fai

Página 59

x510 Series Installation Guide for Virtual Chassis Stacking41USB PortThe management panel has a USB port. You may use the port to store configuration

Página 60

Chapter 1: Overview42Console PortThe Console port is used to establish a management session with the switch to configure its features and parameter se

Página 61

x510 Series Installation Guide for Virtual Chassis Stacking43Power SuppliesThe x510 Series switches have two AC power supplies with separate AC connec

Página 62

Chapter 1: Overview44

Página 63 - Planning a Stack

45Chapter 2Virtual Chassis StackingThe sections in this chapter are: “Overview” on page 46 “Stacking Slots” on page 47 “Stacking Transceivers” on p

Página 64

Chapter 2: Virtual Chassis Stacking46OverviewThe Virtual Chassis Stacking (VCStack) feature allows you to connect up four x510 Series switches to form

Página 65 - Unpacking the Switch

x510 Series Installation Guide for Virtual Chassis Stacking47Stacking SlotsThe x510 Series Switches come with two stacking slots. The slots are the la

Página 66

Chapter 2: Virtual Chassis Stacking48Stacking TransceiversYou connect the switches of the VCStack with the stacking transceivers listed in Table 10 an

Página 67 - Chapter 4

x510 Series Installation Guide for Virtual Chassis Stacking49Here are the transceiver guidelines: The stacking transceivers may only be used in the s

Página 68

5Preface ...

Página 69

Chapter 2: Virtual Chassis Stacking50Stacking Port TopologiesThe switches of a stack are connected with the S1 and S2 ports and the stacking transceiv

Página 70 - 3. Turn the switch over

x510 Series Installation Guide for Virtual Chassis Stacking51Figure 15. Stack of Four Switches in the Linear TopologyThe second topology is called the

Página 71

Chapter 2: Virtual Chassis Stacking52Figure 16. Stack of Two Switches in the Ring TopologyFigure 17 on page 53 is an example of a stack of four switch

Página 72

x510 Series Installation Guide for Virtual Chassis Stacking53Figure 17. Stack of Four Switches in the Ring TopologyThe topologies are the same in term

Página 73 - Chapter 5

Chapter 2: Virtual Chassis Stacking54Master and Member SwitchesThe stack has one master switch. The functions of the master switch include: Coordinat

Página 74

x510 Series Installation Guide for Virtual Chassis Stacking55ID Numbers Each switch must be assigned an ID number. The range is 1 to 4 and the default

Página 75 - Management

Chapter 2: Virtual Chassis Stacking56Specifying Ports in the Command Line InterfaceThe command line interface in the management software on the switch

Página 76 - Activating

57Chapter 3Beginning the InstallationThe chapter contains the following sections: “Reviewing Safety Precautions” on page 58 “Choosing a Site for the

Página 77

Chapter 3: Beginning the Installation58Reviewing Safety PrecautionsPlease review the following safety precautions before beginning the installation pr

Página 78

x510 Series Installation Guide for Virtual Chassis Stacking59WarningClass I Equipment. This equipment must be earthed. The power plug must be connecte

Página 79 - Cabling the Stacking Ports

Contents6Stacking Transceivers...

Página 80

Chapter 3: Beginning the Installation60CautionRisk of explosion if battery is replaced by an incorrect type. Replace only with the same or equivalent

Página 81 - Transceiver

x510 Series Installation Guide for Virtual Chassis Stacking61WarningReliable earthing of rack-mounted equipment should be maintained. Particular atten

Página 82

Chapter 3: Beginning the Installation62Choosing a Site for the SwitchesObserve these requirements when planning the installation of the switches of a

Página 83

x510 Series Installation Guide for Virtual Chassis Stacking63Planning a StackHere are the guidelines to planning a stack: A stack can have up to four

Página 84

Chapter 3: Beginning the Installation64Table 11. Operating Distances of the AT-StackOP/0.3 TransceiverFiber TypeMinimum Modal Bandwidth @ 850 nm (MHz*

Página 85

x510 Series Installation Guide for Virtual Chassis Stacking65Unpacking the SwitchFigure 19 lists the items that come with the switch. If any item is m

Página 86

Chapter 3: Beginning the Installation66

Página 87

67Chapter 4Installing the Switches on a Table or in an Equipment RackThe procedures in this chapter are: “Installing the Switches on a Table or Deskt

Página 88

Chapter 4: Installing the Switches on a Table or in an Equipment Rack68Installing the Switches on a Table or DesktopYou may install the switches on a

Página 89 - Powering On the Stack

x510 Series Installation Guide for Virtual Chassis Stacking69Installing the Switch in an Equipment RackThis procedure requires the following items: E

Página 90

7Figure 1: Front Panels of the AT-x510-28GTX and AT-x510-28GPX Switches ...19Figure 2:

Página 91

Chapter 4: Installing the Switches on a Table or in an Equipment Rack703. Turn the switch over.4. Attach the two rack mount brackets to the sides of t

Página 92

x510 Series Installation Guide for Virtual Chassis Stacking71Figure 23. Attaching the Equipment Rack Brackets (Continued)5. While another person holds

Página 93

Chapter 4: Installing the Switches on a Table or in an Equipment Rack72

Página 94

73Chapter 5Verifying the Status of VCStackThe procedures in this chapter are: “Verifying the Status of VCStack” on page 74 “Activating the VCStack F

Página 95 - Verifying the Stack

Chapter 5: Verifying the Status of VCStack74Verifying the Status of VCStackBefore you install the stacking transceivers to build the stack, you should

Página 96 - Priority Numbers

x510 Series Installation Guide for Virtual Chassis Stacking75Activating the VCStack FeaturePerform the following two procedures to activate the VCStac

Página 97

Chapter 5: Verifying the Status of VCStack76NoteThe port settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulator program. 4.

Página 98

x510 Series Installation Guide for Virtual Chassis Stacking773. Enter the STACK ENABLE command to activate VCStack on the switch, as shown in Figure 2

Página 99

Chapter 5: Verifying the Status of VCStack789. Check the ID LED and do one of the following: If the ID LED is displaying the number 1, 2, 3, or 4, VC

Página 100

79Chapter 6Cabling the Stacking PortsThis chapter contains the following procedures: “Cabling Switches with AT-StackXS/1.0 Transceivers” on page 80

Página 101 - Cabling the Networking Ports

Figures8Figure 50: Switch Initialization Messages (Continued) ...

Página 102

Chapter 6: Cabling the Stacking Ports80Cabling Switches with AT-StackXS/1.0 TransceiversTo cable the switches of the stack with AT-StackXS/1.0 transce

Página 103

x510 Series Installation Guide for Virtual Chassis Stacking81Figure 34. Removing the Dust Cover from the AT-StackXS/1.0 Transceiver4. Position the tra

Página 104

Chapter 6: Cabling the Stacking Ports82Figure 35. Installing the AT-StackXS/1.0 Transceiver in Slot S15. Remove the dust cover from the S2 slot in the

Página 105 - AT-x510-28GSX

x510 Series Installation Guide for Virtual Chassis Stacking83Figure 36. Removing the Dust Plug from the S2 Slot6. Remove the dust cover from the conne

Página 106

Chapter 6: Cabling the Stacking Ports84Figure 37. Installing the AT-StackXS/1.0 Transceiver in Slot S28. Repeat this procedure to connect additional s

Página 107

x510 Series Installation Guide for Virtual Chassis Stacking85Cabling Switches with AT-StackOP/0.3 or AT-StackOP/9.0 TransceiversFor guidelines to cabl

Página 108

Chapter 6: Cabling the Stacking Ports86Figure 39. Installing the AT-StackOP/0.3 or AT-StackOP/9.0 Transceiver4. Remove the dust cover from the transce

Página 109

x510 Series Installation Guide for Virtual Chassis Stacking87Figure 40. Removing the Dust Cover from a Stacking Transceiver5. Verify the position of t

Página 110

Chapter 6: Cabling the Stacking Ports88Figure 42. Connecting the Fiber Optic Cable to the Stacking Transceiver7. Repeat this procedure if the switch i

Página 111 - Troubleshooting

89Chapter 7Powering On the StackThis chapter contains the following procedures: “Powering On the Switches Individually” on page 90 “Powering On the

Página 112

9TablesTable 1: Twisted Pair Cable for the 10/100/1000Base-T Ports ...

Página 113

Chapter 7: Powering On the Stack90Powering On the Switches IndividuallyThis procedure explains how you can control the assignment of the ID numbers of

Página 114

x510 Series Installation Guide for Virtual Chassis Stacking91Figure 43. Plugging in the AC Power CordsConsider the following items as you power on the

Página 115 - Technical Specifications

Chapter 7: Powering On the Stack92As the new switch boots up, the first switch, which has the ID number 1 and at this point is the master switch of th

Página 116 - Environmental Specifications

x510 Series Installation Guide for Virtual Chassis Stacking93Powering On the Switches SimultaneouslyIf you want the switches of the stack to use their

Página 117 - Certifications

Chapter 7: Powering On the Stack94WarningPower cord is used as a disconnection device. To de-energize equipment, disconnect the power cord.  E3NotePl

Página 118

x510 Series Installation Guide for Virtual Chassis Stacking95Verifying the StackTo verify stack operations, perform the following procedure:1. Establi

Página 119

Chapter 7: Powering On the Stack96 Otherwise, go to Chapter 8, “Cabling the Networking Ports” on page 101, to continue with the installation.Setting

Página 120 - Transceivers

x510 Series Installation Guide for Virtual Chassis Stacking97Figure 46. Returning to the Privileged Exec Mode4. Enter the WRITE command to save your c

Página 121

Chapter 7: Powering On the Stack98Monitoring the Initialization ProcessesYou may monitor the initialization sequence of the stack by connecting a term

Página 122

x510 Series Installation Guide for Virtual Chassis Stacking99Figure 49. Switch Initialization Messages (Continued)Received event poefw.doneStarting ba

Comentários a estes Manuais

Sem comentários