AT-S85 and AT-S97 Management Software User’s Guide
91
Examples
This command assigns the name “mm vata” to a management module in a
chassis with the ID 0:
system set module id=0/m name="mm vata"
This command sets the temperature threshold to 55° C for a media
converter module in slot 2 in a chassis with the ID 0:
system set module id=0/2 temperature-threshold=55
This command assigns the name “124 mod-ab” and a temperature
threshold of 70° C to the media converter module in slot 2 of a chassis with
the ID 1:
system set module id=1/2 name="124 mod-ab"
temperature-threshold=70
This command assigns a temperature threshold of 70° C to the power
supply module or fan module in slot A. The chassis has the ID 1:
system set module id=1/a temperature-threshold=70