88
6. Type 2 to select Destination Module.
The following prompt is displayed.
Enter Destination Module: [1 to 8] ->
7. Enter the number of the module you wish to set as a destination
module.
8. Type 3 to select Destination Port.
The following prompt is displayed.
Enter Destination Port: (01-24) (0=None):
9. Enter the number of the port you wish to set as a destination port.
10. Type 4 to select Source Module.
The following prompt is displayed.
Enter Source Module: [1 to 8] ->
11. Enter the number of the module you wish to set as a source module.
12. Type 5 to select Source Port.
The following prompt is displayed.
Enter Source Port: (01-24) (0=None):
13. Enter the number of the port you wish to set as a source port.
14. Type S to select Save Configuration changes.
The port mirror is immediately activated on the switch. You could
now connect a data analyzer to the mirror port to monitor the
traffic on the selected ports.
3 - Destination
Port
Mirror port to which traffic will be sent to. This port
cannot be part of a trunk or be one of the mirroring
ports.
Possible settings for this parameter are:
None (default)
1 to 24
4 - Source Module
Mirroring module whose traffic needs to be mirrored.
5 - Source Port
Mirroring port whose traffic needs to be mirrored.
Possible settings for this parameter are:
None (default)
1 to 24