AT-S62 Menus Interface User’s Guide
Section II: Advanced Operations 209
Modifying the
Event Log Full
Action
This procedure explains how to control what the log will do once it
reaches its maximum capacity of 4,000 events. You have two options.
The first is to have the switch delete the oldest entries as it adds new
entries to the log. The second is to have the switch stop adding entries,
so as to preserve the existing log contents.
This procedure is only relevant when viewing the event log through a
local or remote management session. If you defined syslog servers, the
switch continues to send events to a syslog server even when the log is
full.
To configure the event log, do the following procedure:
1. From the Main Menu, type 5 to select System Administration.
2. From the System Administration menu, type 8 to select Event Log.
The Event Log menu is shown in Figure 60 on page 204.
3. From the Event Log menu, type L to select Configure Log Outputs.
The Configure Log Outputs menu is shown in Figure 62.
Figure 62 Configure Log Outputs Menu
This menu includes any syslog servers you might have defined.
4. Type 2 to select Modify Log Output.
The following prompt is displayed:
Enter output ID to modify [1 to 20] -> 1
5. Press Return to accept the default value 1.
The following prompt is displayed:
Allied Telesyn Ethernet Switch AT-8524M - AT-S62
Production Switch
User: Manager 11:20:02 02-Jan-2004
Configure Log Outputs
OutputID Type Status Details
-----------------------------------------------------------
1 Temporary Enabled Wrap on Full
1 - Create Log Output
2 - Modify Log Output
3 - Delete Log Output
4 - View Log Output Details
R - Return to Previous Menu
Enter your selection?