Section II: Advanced Operations 331
Power Status
Whether power is being supplied to the device. ON means that
the port is providing power to a powered device. OFF means the
device is not a powered device, PoE has been disabled on the
port, or no device is connected to the port.
Power Consumed
The amount of power in milliwatts currently consumed by the
powered device connected to the port. If the port is not
connected to a powered device, this value will be 0 (zero).
Power Limit
The maximum amount of power allowed by the port for the
device. The default is 15,400 milliwatts (15.4 W). To adjust this
value for a port, refer to Configuring PoE Port Settings on page
325.
Power Priority
The port priority. This can be Critical, High, or Low. For an
explanation of this parameter, refer to Port Prioritization on page
321. To adjust this value, refer to Configuring PoE Port Settings on
page 325.
Power Class
The IEEE 802.3af class of the device. For an explanation of this
parameter, refer to PoE Device Classes on page 322. This
parameter cannot be changed.
Voltage
The voltage being delivered to the powered device
Current
The current drawn by the powered device.