Chapter 13: Event Log
Section II: Advanced Operations 214
For example, the setting of DEFAULT assigns all port mirroring
events a code of 22 and all encryption key events a code of 4.
Your other option is to assign all events from a switch the same
numerical code using one of the following facility level settings:
1 - LOCAL1
2 - LOCAL2
3 - LOCAL3
4 - LOCAL4
5 - LOCAL5
6 - LOCAL6
7 - LOCAL7
Each setting represents a predefined RFC 3164 numerical code.
The code mappings are listed in Table 6.
9 Clock daemon Time- based modules:
- TIME (system time and SNTP)
- RTC
22 Local use 6 Physical interface and data link
modules:
- PCFG
- PMIRR
- PTRUNK
- STP
- VLAN
23 Local use 7 SYSTEM events related to major
exceptions.
16 Local use 0 All other modules and events.
Table 6 Numerical Code and Facility Level Mappings
Numerical
Code
Facility Level Setting
17 LOCAL1
Table 5 Applicable RFC 3164 Numerical Code and AT-S62 Module
Mappings