14. Provisioning the iMG/RG iMG/RG Diagnostics
855
AlliedView NMS Administration Guide
Disabled - Applies to call servers that do not require SIP Subscribe. Notifications are enabled.
Enabled - Applies to call servers that require SIP Subscribe. Notifications are enabled.
For iMGs running software release 4.2.3 and later, the options for SIP Subscribe Message Summary are:
Disabled - Support for notifications is disabled on the iMG.
Enabled/Passive - Applies to call servers that do not require SIP Subscribe. Notifications are enabled.
Enabled/Active - Applies to call servers that require SIP Subscribe. Notifications are enabled.
14.12.3 MGCP Persistence
For iMG 1000 and iMG 2000 devices running software release 4.3 and later, you can configure four parameters for MGCP
Persistence: Digits, Hook Flash, Off Hook and On Hook. The following rules apply:
The parameters apply to MGCP profiles only, such as Genband C15 and Metaswitch. They are grayed out when the VOIP
type is SIP.
For MGCP NCS profiles, such as a Genband profile for the G6, the MGCP Persistence settings for Hook Flash, On Hook
and Off Hook are always enabled and changes to these settings are ignored. MGCP Persistence for Digits is disabled by
default but you can change it to enabled if necessary.
14.13 iMG/RG Diagnostics
This section lists and describes the diagnostic features that are available for the various iMG/RG models.
14.13.1 iMG GR-909 Diagnostics
The NMS supports GR-909 diagnostics for the following voice-enabled devices:
MOD iMGs and the iMG726-BD-ON running software release 3.7.4 or higher
iMGs running software release 4.3 or higher except models iMG1525 and iMG1525RF. These two models do not support
GR-909 diagnostics.
GR-909 diagnostics includes internal and external tests. For internal tests, the physical wiring is disconnected from the device
for the test so only the internal circuitry is tested. For external tests the wiring remains intact and the whole system is
tested.
For MOD iMGs and the iMG726-BD-ON, you can display GR-909 internal and external tests as well as voice line status and
diagnostic results. You can also disable and enable voice lines from the panel. iMGs running software release 4.3 or higher
display external GR-909 diagnostics only.
To run GR-909 diagnostics on an iMG:
1. In the Network Objects panel, select Network Inventory > iMG/RGs to open the iMG/RGs screen.
2. Select the desired iMG, right-click and select View/Modify Details.
3. Select the iMG/RG tab, then select the Diagnostics tab.
4. In the Diagnostics panel, select the VOIP tab to display the Voice Diagnostics panel.
Note: For MOD iMGs and the iMG726-BD-ON, the Diagnostics panel contains two tabs: VOIP and LAN. For iMGs running software
release 4.3 or higher, the Diagnostics panel contains just the VOIP tab.
The Voice Diagnostics panel display varies depending on the iMG.
Vista de página 863
1 2 ... 859 860 861 862 863 864 865 866 867 868 869 ... 994 995

Comentários a estes Manuais

Sem comentários