Chapter 4: Configuring the AT-CV5M02 Management Card
106
4. Select the Syslog IP Address field and enter the IP address of the
syslog server on your network. To stop the management card from
sending any further event messages to the server, enter 0.0.0.0 as the
server address.
5. To specify a facility code, select Syslog Facility Code and enter a
facility code for the events. The management card adds this code to
the messages when it sends the messages to the syslog server. The
range is 0 to 23. The default is 1. The numerical codes are defined in
the RFC 3164 standard.
6. Click Update.
7. To save your changes in the master configuration file, select the Files
tab in the Configuration window and click Save System
Configuration and All Cards Configurations and Apply.