802.1x Commands
Page 319
Syntax
dot1x timeout supp-timeout seconds
no dot1x timeout supp-timeout
Parameters
seconds — Time in seconds that the device waits for a response to an EAP-request frame from the client
before resending the request. (Range: 1- 65535 seconds)
Default Configuration
Default timeout period is 30 seconds.
Command Mode
Interface configuration (Ethernet) mode
User Guidelines
The default value of this command should be changed only to adjust for unusual circumstances, such as
unreliable links or specific behavioral problems with certain clients. and authentication servers
Example
The following example sets the timeout period before retransmitting an EAP-request frame to the client to 3600
seconds.
dot1x timeout server-timeout
The dot1x timeout server-timeout Interface Configuration mode command sets the time that the device waits for
a response from the authentication server. Use the no form of this command to return to the default configuration.
Syntax
dot1x timeout server-timeout seconds
no dot1x timeout server-timeout
Parameters
seconds — Time in seconds that the device waits for a response from the authentication server.
(Range: 1-65535 seconds)
Default Configuration
The timeout period is 30 seconds.
Command Mode
Interface configuration (Ethernet) mode
Console(config-if)
#
dot1x timeout supp-timeout
3600